• Ruggedization
against high shock, vibration, and humidity
• MS connectors
• 400 Hz input and / or output
• Chassis Slide guides
• Solid state transfer switch (Standard
on some models)
• Additional battery back-up time (up to
24 hours available)
• Premium batteries with up to 10 year life
• Additional Meters
• RS-232
Interface Port
• Custom Paint
• Custom Enclosures
• RUPS
2000 UPS monitoring and controlling software.
|
|

Three-Phase Input
Voltage (select): 120/208
VAC, 220/380 VAC, or 277/480 VAC +/- 10%
Frequency: 50 Hz, 60 Hz or 400
Hz, and 50/60 Hz available
Connections: Line cord, terminal
block or MS connectors
Three-Phase Output
Voltage (specify): 120/208 VAC,
220/380 VAC, or 277/480 VAC
Frequency: 50 Hz, 60 Hz, 400 Hz,
50/60 Hz available
Voltage regulation: +/-2% no load
to full load
Dynamic voltage regulation: +/-10%
for 100% load change
Frequency regulation: +/-0.5% no
load to full load (Free running)
Distortion: Less than 5% T.H.D.
Power factor: 0.7 lead to 0.7 lag
Harmonic distortion: 5% THD
Efficiency at full load: 75% to
80% AC-AC Typical
Sync & phase lock range*: +/-3
Hz Typical
Efficiency: Approximately 80%
input-to-output at full load (Typical)
Power factor: 0.75 lead to 0.75
lag
Cooling: Forced air (rear exhaust)
Operating temperature: -20°
to +40° C
Storage temperature: -25° to
+65° C
Humidity: To 95% non-condensing
Acoustic noise: Less than 55 dBA
at 5'
Dimensions & Weights
3-8 KVA UPS Drawer Dimensions:
10.5" High x 19" Wide x 24" Deep
(Typical)
External Battery Drawer Dimensions:
7" High x 19" Wide x 20.75" Deep
External Battery Drawer Weight:
200 Pounds (typical)
Overload: 125% for 10 minutes
1000% for one cycle
(Via optional static transfer switch)
MTBF: 30,000 hours per MIL-HDBC-217
MTTR: 30 minutes per qualified
personnel
* SYNC disabled on certain models
Environmental
Ambient operating temperature range: -20°
to +50° C*
Storage temperature range: -40°
to +60° C*
Humidity: to 95% RH non-condensing
– Designed to meet MIL-STD-810. All boards
conformal coated with Acrylic MIL-I-46058 Type R.
Shock: 20g, 11 mS half sinewave
– Designed to meet MIL-STD-810 optionally
EMI: Designed to meet FCC Part
15, Class A. Designed to meet MIL-STD-461 with optional
additional filtering.
*For best results, batteries must be kept at 25
degrees Celsius ambient temperature. Extreme low
temperatures will result in reduced run time, while
extreme high temperatures result in significantly
reduced battery lifespan.
Elevation: 15,000 ft. (4,572 m)
operating**
40,000 ft. (12,192 m), non-operating**
**For batteries, please follow battery manufacturer
instructions regarding recommended elevation parameters.
Audible noise: Less than 55 dBA
at 5 ft. (1.5 m)
Transportation and handling: MIL-STD-810C
Protective Features
Circuit Breakers: Battery Charger
Input, Battery Input
Fuses: Inverter Input, AC Bypass
Input
Low Battery Shut Off Overload Protected
Thermal Protection Output Short Circuit Protection
Transient Protection (available to MIL-STD-1399
Audible Alarm with Silence Switch
Standard Remote Contacts
Major Alarm: Logic Fault, Low Battery,
Over-Temperature, UPS Off, UPS Overloaded
Minor Alarm: Utility Off, Load on Utility
Standard Front Panel Diagnostics
System Status: Green/Red
Utility Off: Red
UPS Off: Red
Low Battery: Red
Logic Fault: Red
UPS Overload: Red
Over-Temperature: Red
Load on Utility: Red
AC & DC Voltage: Meter
|