MODEL SELECTION
SPECS/STD FEATURES
DISCHARGE TIMES
  TRUE ON-LINE FREESTANDING UPS
 


NOVA PULSAR SERIES
3KVA / 15KVA




Nova Electric proudly introduces our family of 3-15 KVA True On-Line UPS Systems. This attractive new freestanding line is designed specifically for professional and commercial applications. Protect your servers ,laser printers, routers, hubs and communications equipment.

 

PULSAR SERIES UPS SPECIFICATIONS


MODEL
P11-3K
P11-4K
P11-5K
P11-6.25K
P11-8K
P11-10K
P11-12K
P11-15K
CAPACITY   3KVA/2.1KW 4KVA/3KW 5KVA/4KW 6.25KVA/5KW 8KVA/6.4KW 10KVA/8KW 12KVA/8.4W 15KVA/10.5W
INPUT
VOLTAGE CHOOSE: 100 VAC, 110VAC, 220VAC, 230VAC OR 240VAC, SINGLE PHASE; 120/208VAC OR 220/380VAC
VOLTAGE RANGE +/- 20% (OPTION +/-40%)
FREQUENCY 50Hz or 60Hz +/-5%
PHASE SINGLE OR THREE PHASE (USER MUST SPECIFY WHEN ORDERING)
OUTPUT
VOLTAGE 100VAC, 110VAC, 220VAC, 230VAC OT 240 VAC, SINGLE PHASE
VOLTAGE REGULATION +/-1%
FREQUENCY/REGULATION 50Hz OR 60 Hz WITH REGULATION BETTER THAN +/-0.5%
LOAD POWER FACTOR FROM 0.7 LAG TO 1.0 (UNITY )
HARMONIC DISTORION PURE SINEWAVE WITH LESS THAN 3% THD AT 100% LINEAR LOAD
OUTPUT LOAD CREST FACTOR MAXIMUM 3:1
EFFICIENCY AC TO AC >85%
BATTERY BATTERY TYPE SEALED LEAD ACID BATTERY, MAINTENANCE FREE
BATTERY SIZE 12V/7AH (ALT:HR1234 HIGH RATE)
NUMBER OF BATTERIES (INTERNAL)
*
16
16
16
*
*
*
*
BACK UP TIME (ALT) MINUTES
EXT
10(14)
7(11)
5(6)
EXT
EXT
EXT
EXT
RECHARGE TIME 8-10 HOURS TO 90% AFTER COMPLETE DISCHARGE
CHARGER BUILT-IN CURRENT SLECTABLE CHARGER UP TO 10 AMP OPTION
TRANSFER TIME AC FAULT ZERO INTERRUPTION OF THE AC OUTPUT
UPS TO BYPASS OR VICE VERSA LESS THAN 4mS
INDICATOR LCD AUTOMATICALLY CONFIGURES TO MONITOR VOLTAGE, FREQUENCY , LOADING AND BATTERY SIMULTANEOUSLY, BLACKOUT & OVERLOAD HISTORICAL DATA.
LED

LINE: GREEN LED; BY-PASS : YELLOW LEAD
INVERTER: GREEND LED; FAULT: RED LED
BATTERY LOW: YELLOW LEAD; OVERLOAD: YELLOW LEAD

AUDIBLE ALARM BATTERY DISCHARGE SOUNDS EVERY 4 SECONDS, MUTE AFTER 90 SECONDS
BATTERY LOW SOUNDS EVERY SECOND
OVERLOAD CONTINUOUSLY BEEPS
FAULT CONTINUOUSLY BEEPS
PROTECTION OVERLOAD 150% DELAY 30 SECONDS, THEN TRANSFER TO BYPASS & AUTO RE-TRANSFER
SHORT CIRCUIT CURRENT LIMITED AND CUT-OFF, FUSE AND CIRCUIT BREAKER
BATTERY LOW BATTERY SHUTDOWN AND BATTERY CIRCUIT BREAKER
UPS FAULT BYPASS, LOAD SUPPLIED FROM THE MAINS IN LESS THAN 2mS.
EMI FILTER 10-100KHz AT 40dB; 100KHz-100 MHz AT 70dB
EMI/AMC EN50091-2, CE APPROVED
OVER TEMPERATURE INVERTER AUTO CUT-OFF WHEN HEATSINK TEMP. OVER 80°C, THEN TRANSFER TO BYPASS
DIMENSION DEPTH INCH (MM)
19.7(500)
22.8(578)
22.8(578)
22.8(578)
13.4(340)
13.4(340)
13.4(340)
15(380)
WIDTH INCH (MM)
7(180)
9.1(230)
9.1(230)
9.1(230)
18.9(480)
18.9(480)
18.9(480)
18.9(480)
HEIGHT INCH (MM)
14.2(360)
27(685)
27(685)
27(685)
33.3(685)
33.3(685)
33.3(685)
35(885)
WEIGHT NET WEIGHT LBS (KG)
73(33)
228(104)
238(108)
253(115)
253(115)
260(118)
264(120)
440(220)
ENVIRONMENT OPERATING TEMPERATURE
0-40 °C: 32-104 °F
RELATIVE HUMIDITY
UP TO 95% (NON CONDENSING )
NOISE LEVEL (AT 3 FEET) <48 dB
<58dB
INTERFACE CONTACT CLOSURES SUPPORTS MEGATEC RUPS UPS MONITORING SOFTWARE
SMART RS-232 INTERFACE SUPPORT MEGATEC RUPS II/UPSilon 2000 MONITORING SYSTEM

BACK TO TOP


TYPICAL DISCHARGE TIMES FOR VARIOUS BATTERIES AND LOADS FOR PULSAR UPS SERIES

KW LOAD
1.0
1.5
2.0
2.4
3.0
3.5
4.0
4.5
5.0
5.2
6.0
6.4
7.0
7.5
8.0
8.4
9.0
9.5
10.0
10.5
1 Set of (12V/7Ah battery *16)
45
24
18
14
10
9
7
6
5
4.8
4
---
---
---
---
---
---
---
---
---
1 Set of (HR1234 battery *16)
54
35
25
20
14
13
9
8
6
5
4
3
---
---
---
---
---
---
---
---
2 Sets of (12V/7Ah battery *16)
110
60
42
31
24
20
18
15
13
12
10
10
9
8
7
6.5
6
5.5
5
4.5
2 sets of (HR1234 battery *16)
150
86
54
45
35
24
23
19
17
16
14
13
12.5
12
11
9.5
8.5
8
7
6
3 Sets of 12V/7Ah battery *16)
180
11
74
55
42
33
26
24
21
20
18
16.5
15
13.5
12.5
12
11
10.3
9.5
9
3 Sets of (HR1234 battery *16)
230
145
100
74
54
45
36
30
27
25
22
20
18.5
17
15
14
13
12.5
11.5
11
4 Sets of (12V/7Ah battery *16)
250
160
120
80
61
51
42
35
30
29
26
24
21
19
17.5
16.5
15
14
13
12
4 Sets of (HR1234 battery *16)
316
195
140
105
75
64
52
45
38
36
30
28
25
22
20
19
18
17
16
15
5 sets of (12V/7Ah battery *16)
330
205
150
115
82
70
56
50
42
40
32
30
27
24
22
21
19
18
17
16
5 Sets of (HR1234 battery *16)
422
262
182
152
102
82
76
62
52
51
43
41
35
31
28
27
24
22
21
20
6 Sets of (12V/7Ah battery *16)
420
260
180
150
100
80
75
61
52
50
40
40
34
30
28
26
24
22
21
20
6 Sets of (HR1234 battery *16)
520
310
205
185
135
105
95
82
72
65
54
52
50
45
40
33
31
30
28
26
7 Sets of (12V/7Ah battery *16)
500
300
220
180
130
100
90
77
67
62
51
48
42
40
35
31
30
28
26
24
7 Sets of (HR1234 battery *16)
630
370
270
220
180
130
120
97
85
76
69
61
54
52
48
44
39
37
35
32
1 Set of (12V 65Ah battery *16)
680
415
300
245
195
160
140
115
97
88
79
75
66
59
54
51
47
42
39
35
1 Set of (12V/100Ah battery *16)
1050
710
530
390
310
260
225
194
160
165
140
122
113
104
95
86
80
74
67
62
1 Set of (12V/200Ah battery *16)
2100
1450
1050
890
705
595
485
425
375
360
310
299
263
240
226
210
198
187
175
160


Notes:
1. All battery Run times are approximate at the specified load 25 degrees centigrade.
2. Other battery choices are available, including larger free standing enclosures
3. Multiple strings of batteries can be made up by paralleing battery enclosures as appropiate

BACK TO TOP

 

3KVA - 4KVA PULSAR ON-LINE UPS SYSTEMS 1 PHASE OUTPUT

TYPICAL POPULAR
MODEL NUMBERS
KVA
KW
I/O
FREQ
INPUT
VAC
OUTPUT
VAC
UPS
EST
Kgs
UPS
EST
Lbs
SIZE(mm)
SIZE(in)
BATTERY
RUN TIME
(MIN)
W
D
H
W
D
H
P11-3K60-120-120
3
2.1
60
120
120
33
73
180
500
360
7.0
19.7
14.2
EXTERNAL
N/A
P11-3K60-120/208-120
3
2.1
60
120/208
120
33
73
180
500
360
7.0
19.7
14.2
EXTERNAL
N/A
P11-3K50-220-220
3
2.1
50
220
220
33
73
180
500
360
7.0
19.7
14.2
EXTERNAL
N/A
P11-3K50-220-220
3
2.1
50
220
220
33
73
180
500
360
7.0
19.7
14.2
EXTERNAL
N/A
P11-4K60-120-120
4
3
60
120
120
60
123
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-4K60-120/208-120
4
3
60
120/208
120
60
123
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-4K50-220-220
4
3
50
220
220
60
123
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-4K50-220/380-220
4
3
50
220/380
220
60
123
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-4K60-120-120-10M
4
3
60
120
120
104
228
230
578
685
9.1
22.8
27
12V7 AH 16PCS
10
P11-4K50-220-220-10M
4
3
50
220
220
104
228
230
578
685
9.1
22.8
27
12V7 AH 16PCS
10
P11-4K60-120-120-14M
4
3
60
120
120
106
233
230
578
685
9.1
22.8
27
HR1234, 16 PCS
14
P11-4K50-220-220-14M
4
3
50
220
220
106
233
230
578
685
9.1
22.8
27
HR1234, 16 PCS
14
                               
BATTERY PACKS
PPC12/7-16-XXK
53
117
180
500
360
7
19.7
14.2
12V7 AH 16PCS
PPC12/7-32-XX
130
286
480
340
845
18.9
13.4
33.3
12V7 AH 32 PCS
PPC12/7-48-XXK
170
374
480
340
845
18.9
13.4
33.3
12V7 AH 48 PCS
 
PPCHR1234-16-XXK
56
123
180
500
360
7
19.7
14.2
HR1234, 16 PCS
 
PPCHR1234-32-XXK
132
290
480
340
845
18.9
13.4
33.3
HR1234, 32 PCS
 
PPCHR1234-48-XXK
173
380
480
340
845
18.9
13
33
HR1237, 48 PCS
 

BACK TO TOP


5KVA - 15KVA PULSAR ON-LINE UPS SYSTEMS 1 PHASE OUTPUT
TYPICAL POPULAR
MODEL NUMBERS
KVA
KW
I/O
FREQ
INPUT
VAC
OUTPUT
VAC
UPS
EST
Kgs
UPS
EST
Lbs
SIZE(mm)
SIZE(in)
BATTERY
RUN TIME
(MIN)
W
D
H
W
D
H
P11-5K60-120-120
5
4
60
120
120
67
147
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-5K60-120/208-120
5
4
60
120/208
120
67
147
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-5K50-220-220
5
4
50
220
220
67
147
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-5K50-220/380-220
5
4
50
220/380
220
67
147
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-5K60-120-120-7M
5
4
60
120
120
108
238
230
578
685
9.1
22.8
27
12V7 AH 16 PCS
7
P11-5K50-220-220-7M
5
4
50
220
220
108
238
230
578
685
9.1
22.8
27
12V7 AH 16 PCS
7
P11-5K60-120-120-10M
5
4
60
120
120
110
242
230
578
685
9.1
22.8
27
HR1234, 16 PCS
11
P11-5K50-220-220-10M
5
4
50
220
220
110
242
230
578
685
9.1
22.8
27
HR1234, 16 PCS
11
P11-6.25K60-120-120
6.25
5
60
120
120
74
163
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-6.25K60-120/208-120
6.25
5
60
120/208
120
74
163
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-6.25K50-220-220
6.25
5
50
220
220
74
163
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-6.25K50-220/380-220
6.25
5
50
220/380
220
74
163
230
578
685
9.1
22.8
27
EXTERNAL
N/A
P11-6.25K60-120-120-5M
6.25
5
60
120
120
115
256
230
578
685
9.1
22.8
27
12V7 AH 16 PCS
5
P11-6.25-K50-220-220-5M
6.25
5
50
220
220
115
253
230
578
685
9.1
22.8
27
12V7 AH 16 PCS
5
P11-6.25K60-120-120-6M
6.25
5
60
120
120
117
257
230
578
685
9.1
22.8
27
HR1234, 16 PCS
6
P11-6.25K50-2220-220-6M
6.25
5
50
220
220
117
257
230
578
685
9.1
22.8
27
HR1234, 16 PCS
6
P11-8K60-120-120
8
6.4
60
120
120
115
253
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-8K60-120/208-120
8
6.4
60
120/208
120
115
253
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-8K50-220-220
8
6.4
50
220
220
115
253
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-8K50-220/380-220
8
6.4
50
220/380
220
115
253
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-10K60-120-120
10
8
60
120
120
118
260
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-8K60-120/208-120
10
8
60
120/208
120
118
253
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-10K50-220-220
10
8
50
220
220
118
260
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-10K50-220/380-220
10
8
50
220/380
220
118
260
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-12K60-120/208-120
12
8.4
60
120
120
120
264
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-12K60-120/208-120
12
8.4
60
120/208
120
120
264
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-12K50-220-220
12
8.4
50
220
220
120
264
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-12K50-220/380-220
12
8.4
50
220/380
220
120
264
480
340
845
18.9
13.4
33.3
EXTERNAL
N/A
P11-15K60-120/208-120
15
10.5
60
120/208
120
200
440
480
380
885
18.9
15
35
EXTERNAL
N/A
P11-15K50-220/380-220
15
10.5
50
220/380
220
200
440
480
380
885
18.9
15
35
EXTERNAL
N/A

Notes:
1. External battery packs can be mixed to obtain longer run times. Battery voltage is always 192VDC nominal.
2. Extended warranty is available.
3. Local on site service for turn-on preventive maintenance is offered by factory engineers.
4. Spare parts kits are available depending on needs.
5. EPO option to trip AC and DC breaker available.
6. Replace the XX in the battery pack model with the KVA rating of the matching UPS.
7. Ruggedizing option is available.
8. All above units are 50 or 60 Hz in and out as shown. Units with other inputs and outputs are available.

BACK TO TOP



• Double conversion, IGBT model, true on-line isolated UPS.
• Unique AVR built-in for super wide input voltage range.
• Special air-flow control, suitable for any dirty operation environment.
• User friendly design and simple operation.
• Single control board design, for easy maintenance.
• Constant power, special overload capacity design.
• One touch LCD Display designs; it's very easy to operate.
• MTTR (Mean Time To Replacement) < 30 minutes.

• MTBF (Mean Time Before Failure) > 8000 hrs.
• CE approved
• All models from 3K to 10KVA are used the same Main PCB. Customers only need to keep one board for RMA service.
a. Full Protection
b. Overload protection
c. Short circuit protection
d. Overload constant power protection
e. Static switch protection
f. Over temperature protection
g. DC BUS start-up with current protection
h. Charger board start up: 2-4 seconds delay
i. Two stage phase Lock Loop
j. This series could be connected with generator.
• Option to schedule UPS on/off times

• The control board and other main components are in the front side that is very easy to do the maintenance service.
• Built-in high capacity battery charger for long backup time.
• Front side operation design for easy installation and maintenance
• Very compact and light design easy to fit into any office corner.
• Smart communication function support MEGATEC RUPSII monitoring software.
• Parallel operation (optional) Connect up to 8 units to increase the capacity.
• The charger board is designed for CCV (Constant Current Constant Voltage) that could extend the battery life two times (3-6 years) including the battery high voltage protection and O/P short circuit protection.



   


Please click here to request more information on this product.
 
 