True On_line Double Conversion
To ensure clean, no-break power for a wide range of mission-critical applications. |
|
|
| |
|
|
Advanced Microprocessor Control
Power failure, power restores, battery failure or other events will be detected and the user informed. A shutdown will be initiated when the batteries are exhausted or a critical technical problem occurs
|
|
|
| |
|
|
| Manual Bypass Switch
Failsafe internal automatic bypass switch with manual control to ease of maintenance. |
|
|
| |
|
|
Green Mode Function
The NAET Series switches to bypass when no load is present, but immediately switches back to inverter when the load returns. This feature offers more economical operation when power supply is more reliable without compromising the protection of the load |
|
* UPSilon via RS 232 |
| |
|
|
| Easy to Read Visual Display
A simple, clear visual display at the front of the unit gives an immediate indication of system status.
|
|
* Cruiser via RS 232 |
| |
|
|
RS 232
The UPS management software is installed on a server or workstation connected to each UPS via the serial port. |
|
|
| |
|
|
Integrated Smartcard Slot
This allows the user to take advantage of a growing range of add-on cards providing facilities such as SNMP, remote web browser-based management, along with USM, AS 400, and DB9 cards.
|
|
* RUPS via Contact Closure (DB9) |
| |
|
|
Optional Specialized UPS Management
Software
Highly manageable power protection for sensitive equipment. Retaining the the legendary reliability of its predecessor, the NAET Series brings high-end features and manageability to even the smallest unit in the NAET range. |
|
|
| |
|
|
SMALL FOOTPRINT
Compact tower, designe to be installed in an office or computer room, taking up very little valuable space in often cramped high resourse areas. |
|
|
| Topology |
True On-Line, Double
Conversion |
| On-battery Output Waveform |
True Sinewave |
| Number of Phase |
Single (1Phase 2W
+ G) |
| Maximum Capacity (VA/W) |
1500VA / 1050W |
1600VA/1120W |
2200VA / 1540W |
2400VA/1680W |
3000VA / 2100W |
3200VA/2240W |
| Nominal Input Voltage |
80 to 138 VAC |
160 to 230 VAC |
80 to 138 VAC |
160 to 276 VAC |
80 to 138 VAC |
160 to 276 VAC |
| Input Voltage Range |
80 to 138 VAC |
160 to 276 VAC |
80 to 138 VAC |
160-276 VAC |
80 to 138 VAC |
160-276 VAC |
| Nominal input Frequency |
50/60 Hz +/- 5 Hz |
| Input PFC |
>0.98 @ full
load |
| Input Short Protection |
Circuit Breaker
on front of the UPS |
| Nominal Output Voltage |
100/110/115/120VAC |
200/208/220/230/240VAC |
100/110/115/120VAC |
200/208/220/230/240VAC |
100/110/115/120VAC |
200/208/220/230/240VAC |
| Output Voltage Regulation |
+/-2% |
| Output T.H.D. |
<3% @ Linear
Load |
| High Efficiency Mode (AC to AC) |
>86% |
>90% |
>90% |
| Crest Factor |
3:1 |
| Start on Battery |
Yes |
| Output Frequency |
50/60Hz (Autotracking) |
| Overload Capacity |
Sustaining at least 120 seconds at 101-110%
load, 111-150% max 12 seconds.
Immediate shutdown and transfer of load to bypass
at 150% load.
Auto transfer back to UPS when overload is removed |
| User Repleaceable Battery |
1 x 48VDC Battery Pack |
96V (2 x 48VDC)Battery Pack |
96V (2 x 48VDC)Battery Pack |
| Typical Backup Time (Full/Half Load) |
6 / 15 minutes |
| Battery Type |
Sealed VRLA 12V7AH;
Hot Swap |
| Recharge Time to 90% |
8 Hours |
| Extended Battery Cabinet |
Extendible Battery
Module in 2U high (comprises 2 x 48VDC Battery Packs) |
| Operation |
Transition from or to battery operation
is accomplished with no interruption of power to the
load. Upon
restoration of input power, the UPS will automatically
resume normal operation and recharge the battery |
| Front Panel Indication |
control panel for all
functions |
| Audible Alarms |
DC
Mode, Low Battery, voltage / Frequency Error, Charger
Fail, Over Load, Fault, PFC Overload |
| Communication Port |
RS 232 Port (Standard);
DB9, AS400, USB Cards (Optional) |
| SNMP Maneageable |
Yes |
| Temperature (Operation/Storage) |
0 ºC to + 40
ºC / -15 to + 50 ºC |
| Relative Humidity |
0% to 95% non-condensing |
| Altitude |
Up to 10,000 ft
(3,000 meters) at up to 40 ºC, without derating |
| Audible Noise |
<45 dBA @ 1
meter |
Dimensions - (WxHxD)
|
150 x 450 x 265 (mm)
5.9 x 17.7 x 10.4 (in)
|
193 x 455 x 323
7.6 x 17.9 x 12.7 (in) |
193 x 485 x 323 (mm)
7.6 x 19.1 x 12.7 (in) |
| Weight (Incl.Batery Packs) |
42 lb 12 / 19 Kgs
|
67.2 lb / 30.5 Kgs |
83.2 lb / 38 Kgs |
| EMI/RFI Compatibility |
FCC Part 15 Class
B, EN50091-2 Class B, EN55022B, IEC/EN61000-3-2(Harmonic Current) |
| Safety |
UL, cUL (CSA) |