| FEATURES
AND BENEFITS
| Flexible
Mounting Orientation
Allows system integrators
more flexibility in designing their backup power
system to maximize space. With the rotatable LCD
design, the user can mount the UPS vertically or
horizontally. 19" Rack Mount adapters are included
with each unit. |
|
 |
| |
|
|
User-Friendly Graphic LCD
This robust LCD
display enables field service engineers to easily
troubleshoot the UPS without opening the box thus
reducing downtime.
|
|
 |
| |
|
|
| Single
Voltage Battery Pack Design
A 48 VDC standard
battery pack design comprised of 4 x 12V7AH is used
in all AET series UPS models and are interchangeable
with each other.
Additional battery drawers can be added to increase
battery runtime. |
|
 |
| |
|
|
Hot-Swappable
Battery
The standard 48
VDC battery pack allows installers to take the headache
out of battery installation. Installers can now
simply slide the used battery pack out of the unit
and replace it with a new pack. All AET battery
packs are interchangeable reducing the risk of system
failures. |
|
 |
| |
|
|
| Light
Weight Design
The AET Model is
specially designed for field installation. The light
weight design requires only a single installer to
put the system in place. This will
significantly reduce on-the-job injuries and installation
fees
|
|
 |
| |
|
|
User-Remote
Interface
The off-site user
can now test, set parameters, monitor power status,
save files, and shutdown the system all via the
remote interface. The user-remote interface includes
SNMP/HTTP Card, RS232, USB, DB9, and AS400 interface. |
|
 |
INTELLIGENT POWER MANAGEMENT
SOFTWARE
| INTERFACE
& OS COMPATIBILITIES |
|
- RS 232 (Standard)
Windows: Win95, WinNT4.0, Win98SE, Win2000, WinMe,
WinXP
Linux: 7.0 ~ 7.3, 8.0 ~ 8.4, 9.0
Mandrake: 8.2, 8.3, 8.4, 9.0
Novell: 4.x, 5.1
|
Windows: Win 98SE, Win2000, WinME,
WinXP |
| |
| |
| Other
major UPS monitoring software and SNMP / HTTP Cards
compatible with all AET Series UPS (For more
information please contact novasales@novaelectric.com) |
-
Internal or External Networking
Card: Net Agent II or USHA PRO (SNMP,HTTP, PPP,
TCP/IP, etc)
|
|
- RUPS via Contact
Closure (DB9)
|
SPECIFICATIONS & MODEL
SELECTION
120 VAC
MODELS
| Topology |
True On-Line, Double
Conversion |
| On-battery Output Waveform |
True Sinewave |
| Number of Phase |
Single (1Phase 2W
+ G) |
| Maximum Capacity (VA/W) |
1500VA / 1050W |
2200VA / 1540W |
3000VA / 2100W |
| Nominal Input Voltage |
120 VAC |
| Input Voltage Range |
80 to 138VAC |
| Nominal input Frequency |
50/60 Hz +/- 5 Hz |
| Input PFC |
>0.98 @ full
load |
| Input Short Protection |
Circuit Breaker
on front of the UPS |
| Nominal Output Voltage |
100/110/115/120VAC |
| Output Voltage Regulation |
Rated Voltage +/-2% |
| Output T.H.D. |
<3% @ Linear
Load |
| High Efficiency Mode (AC to AC) |
>86% |
>88% |
>88% |
| Crest Factor |
3:1 |
| Start on Battery |
Yes |
| Output Frequency |
50/60Hz (Autotracking) |
| Overload Capacity |
Sustaining at least 120 seconds at 101-110%
load, 111-150% max 12 seconds.
Immediate shutdown and transfer of load to bypass
at 150% load.
Auto transfer back to UPS when overload is removed |
| User Repleaceable Battery |
1 x 48VDC Battery Pack |
96V (2 x 48VDC)Battery Pack |
96V (2 x 48VDC)Battery Pack |
| Typical Backup Time (Full/Half Load) |
6 / 17 minutes |
9 / 26 minutes |
6 / 17 minutes |
| Battery Type |
Sealed VRLA 12V7AH;
Hot Swap |
| Recharge Time to 90% |
8 Hours |
| Extended Battery Cabinet |
Extendible Battery
Module in 2U high (comprises 2 x 48VDC Battery Packs) |
| Operation |
Transition from or to battery operation
is accomplished with no interruption of power to the
load. Upon
restoration of input power, the UPS will automatically
resume normal operation and recharge the battery |
| Front Panel Indication |
Front panel menu
driven LCD monitoring and control panel for all
functions |
| Audible Alarms |
DC
Mode, Low Battery, voltage / Frequency Error, Charger
Fail, Over Load, Fault, PFC Overload |
| Communication Port |
RS 232 Port (Standard);
DB9, AS400, USB Cards (Optional) |
| SNMP Maneageable |
Yes |
| Temperature (Operation/Storage) |
0 ºC to + 40
ºC / -15 to + 50 ºC |
| Relative Humidity |
0% to 95% non-condensing |
| Altitude |
Up to 10,000 ft
(3,000 meters) at up to 40 ºC, without derating |
| Audible Noise |
<45 dBA @ 1
meter |
Dimensions - (WxHxD)
Note: Change W to 19 in. for
Rack Mount Configuration
|
426 x 88(2U) x 500 (mm)
16.77 x 3.46 (2U) x 19.7 (in)
|
426 x 176 (4U) x 500 (mm)
16.67 x 6.93(4U) x 19.7 (in) |
426 x 176 (4U) x 500 (mm)
16.67 x 6.93 (4U) x 19.7 (in) |
| Weight (UPS/Batery Packs) |
26.4 / 24.6 lb 12 / 11.2 Kgs
|
29 / 68.7 lb 13.2 / 31.2 Kgs |
29.5 / 69 lb 13.4 / 31.4 Kgs |
| Total Weight |
51lb 23.2Kgs |
97.7lb 44.4Kgs |
98.5lb 44.6kgs |
| EMI/RFI Compatibility |
FCC Part 15 Class
B |
| Safety |
UL, cUL (CSA) |
220
VAC MODELS
| Topology |
True On-Line, Double
Conversion |
| On-battery Output Waveform |
True Sinewave |
| Number of Phase |
Single (1Phase 2W
+ G) |
| Maximum Capacity (VA/W) |
1600VA / 1120W |
2500VA / 1750W |
3200VA / 2240W |
| Nominal Input Voltage |
230 VAC |
| Input Voltage Range |
160 to 276VAC |
| Nominal input Frequency |
50/60 Hz +/- 5 Hz |
| Input PFC |
>0.98 @ full
load |
| Input Short Protection |
Circuit Breaker
on front of the UPS |
| Nominal Output Voltage |
208/220/230/240VAC |
| Output Voltage Regulation |
Rated Voltage +/-2% |
| Output T.H.D. |
<3% @ Linear
Load |
| High Efficiency Mode (AC to AC) |
>86% |
>88% |
>88% |
| Crest Factor |
3:1 |
| Start on Battery |
Yes |
| Output Frequency |
50/60Hz (Autotracking) |
| Overload Capacity |
Sustaining at least 120 seconds at 101-110%
load, 111-150% max 12 seconds.
Immediate shutdown and transfer of load to bypass
at 150% load.
Auto transfer back to UPS when overload is removed |
| User Repleaceable Battery |
1 x 48VDC Battery Pack |
96V (2 x 48VDC)Battery Pack |
96V (2 x 48VDC)Battery Pack |
| Typical Backup Time (Full/Half Load) |
6 / 17 minutes |
9 / 26 minutes |
6 / 17 minutes |
| Battery Type |
Sealed VRLA 12V7AH;
Hot Swap |
| Recharge Time to 90% |
8 Hours |
| Extended Battery Cabinet |
Extendible Battery
Module in 2U high (comprises 2 x 48VDC Battery Packs) |
| Operation |
Transition from or to battery operation
is accomplished with no interruption of power to the
load. Upon
restoration of input power, the UPS will automatically
resume normal operation and recharge the battery |
| Front Panel Indication |
Front panel menu
driven LCD monitoring and control panel for all
functions |
| Audible Alarms |
DC
Mode, Low Battery, voltage / Frequency Error, Charger
Fail, Over Load, Fault, PFC Overload |
| Communication Port |
RS 232 Port (Standard);
DB9, AS400, USB Cards (Optional) |
| SNMP Maneageable |
Yes |
| Temperature (Operation/Storage) |
0 ºC to + 40
ºC / -15 to + 50 ºC |
| Relative Humidity |
0% to 95% non-condensing |
| Altitude |
Up to 10,000 ft
(3,000 meters) at up to 40 ºC, without derating |
| Audible Noise |
<45 dBA @ 1
meter |
Dimensions - (WxHxD)
Note: Change W to 19 in. for
Rack Mount Configuration
|
426 x 88(2U) x 500 (mm)
16.77 x 3.46 (2U) x 19.7 (in)
|
426 x 176 (4U) x 500 (mm)
16.67 x 6.93(4U) x 19.7 (in) |
426 x 176 (4U) x 500 (mm)
16.67 x 6.93 (4U) x 19.7 (in) |
| Weight (UPS/Battery Packs) |
26.4 / 24.6 lb 12 / 11.2 Kgs
|
29 / 68.7 lb 13.2 / 31.2 Kgs |
29.5 / 69 lb 13.4 / 31.4 Kgs |
| Total Weight |
51lb 23.2Kgs |
97.7lb 44.4Kgs |
98.5lb 44.6kgs |
| EMI/RFI Compatibility |
EN50091-2 ClassB,
EN55022B. IEC/EN61000-3-2 (Harmonic Current) |
| Safety |
CE, TUV, GS |
|