Specifications
Electrical
Input Voltage: 105-150 VDC (Extended range available)
Output Voltage: See TableFrequency: 50 Hz, 60 Hz, 400 Hz
(+/-0.5%)
Frequency Regulation: +/-0.5% N.L. to F.L.
Voltage Regulation: +/-1.5% N.L. to F.L.
Efficiency: Approximately 80% (depending on model)
Reactive Load: 0.75 Lead to 0.75 Lag
Distortion: 5% THD, 3% Single Harmonic
Overload: 125% for 5 minutes
| Overload Protection Range: |
Automatic overload &
short circuit protection |
| Sync & Phase Lock Range: |
+/-3 Hz, Typical (50/60
Hz models) |
| Transient Response: |
Approx. 1/4 cycle recovery to
95% of nominal |
Environmental & Mechanical
| Operating Temp: |
-20°C to +50°C Standard
-40°C to +71°C Optional |
Cooling: By internal DC
brushless fan
Vibration: Normal shipping and handling
Shock: 20g, 11 mS half sinewave
Humidity: To 95% RH non-condensing
| EMI: |
Designed to meet FCC Part 15,
Class A, Can
meet MIL-STD-461 with additional filtering |
Applications
GL Series Inverters utilize high frequency PWM topology
for applications with space and weight constraints. All models are
suitable for severe environment and high reliability
applications such as:
- Military programs, vehicular, shipboard
- AC Power from vehicle battery
- Communications
- Shelters
- Utility applications
Standard Features
- Pure Sinewave Output
- Small Size
- Lightweight, extremely compact
- High reliability, MTBF exceeds 100,000 hours
- OV, O.L. and O.T. protected
- MTTR below 30 minutes; modular design
- Withstands high reactive load
- Tight voltage and frequency regulation
- Output fault alarm (relay closure)
- Boards are conformal coated
Available Options
- Ruggedized to meet MIL-STD-810 shock,
vibration and humidity ("R" option)
- Wide temperature range -40°C to +71°C
- Special output voltages and frequencies
- Provision for 3 Phase connection
with 2 more identical units
- 19" Panel mount ("P1" option)
- MS Connectors or outlets
- Custom painting and marking
- Handles
- High inrush for motor start
- Transfer switch to alternate AC source
- Wall mount plate ("W" option)
- Chassis slides (rack mount models only)
- Switchable 50/60 Hz output
|
Contact Us