Introducing
Nova's Rugged 400-1200 VDC Input Galaxy-Series DC-AC Inverters
600-750 VDC Nominal Input / Pure
Sine-Wave Output
For Work Trains, Trolleys,
and Mass Transit Stationary Applications
Partial Standard Model
Selection - Please consult factory for custom applications
60 Hz
MODELS |
OUTPUT
VAC |
OUTPUT
FREQ
(Hz) |
CONTINUOUS
OUTPUT
POWER |
APPROX.
WEIGHT
(LB) |
SIZE
(H x W x L)
(INCHES) |
APPROXIMATE
EFFICIENCY % |
| GH1K60-600 |
120 |
60 |
1
KVA |
100 |
30.0
x 24.7 x 9.2 |
90% |
| GH2K60-600 |
120 |
60 |
2
KVA |
150 |
C/F |
90% |
| GH3K60-600 |
120 |
60 |
3 KVA |
190 |
30.0 x 26.3 x 11.2 |
90% |
| GH5K60-600 |
120 |
60 |
5
KVA |
200 |
30.0
x 26.3 x 11.2 |
90% |
| GH7.5K60-600 |
120 |
60 |
7.5 KVA |
215 |
C/F |
90% |
| GH10K60-600 |
120 |
60 |
10
KVA |
740 |
60.0
x 31.0 x 23.0 |
90% |
| GH15K60-600 |
120 |
60 |
15
KVA |
800 |
60.0
x 31.0 x 23.0 |
90% |
| GH20K60-600 |
120 |
60 |
20
KVA |
900 |
72.0
x 36.0 x 23.0 |
90% |
| GH25K60-600 |
120 |
60 |
25
KVA |
C/F |
C/F |
C/F |
| GH30K60-600 |
120 |
60 |
30
KVA |
C/F |
C/F |
C/F |
50 Hz
MODELS |
OUTPUT
VAC |
OUTPUT
FREQ
(Hz) |
CONTINUOUS
OUTPUT
POWER |
APPROX.
WEIGHT
(LB) |
SIZE
(H x W x L)
(INCHES) |
APPROXIMATE
EFFICIENCY % |
| GH1K50-600
(220) |
220 |
50 |
1
KVA |
100 |
30.0
x 24.7 x 9.2 |
90% |
| GH2K50-600
(220) |
220 |
50 |
2
KVA |
150 |
C/F |
90% |
| GH3K50-600 (220) |
220 |
50 |
3 KVA |
190 |
30.0 x 26.3 x 11.2 |
90% |
| GH5K50-600
(220) |
220 |
50 |
5
KVA |
200 |
30.0
x 26.3 x 11.2 |
90% |
| GH7.5K50-600 (220) |
220 |
50 |
7.5 KVA |
215 |
C/F |
90% |
| GH10K50-600
(220) |
220 |
50 |
10
KVA |
740 |
60.0
x 31.0 x 23.0 |
90% |
| GH15K50-600
(220) |
220 |
50 |
15
KVA |
800 |
60.0
x 31.0 x 23.0 |
90% |
| GH20K50-600
(220) |
220 |
50 |
20
KVA |
900 |
72.0
x 36.0 x 23.0 |
90% |
| GH25K50-600
(220) |
220 |
50 |
25
KVA |
C/F |
C/F |
C/F |
| GH30K50-600
(220) |
220 |
50 |
30
KVA |
C/F |
C/F |
C/F |
3-PHASE
MODELS* |
OUTPUT
VAC |
OUTPUT
FREQ
(Hz) |
CONTINUOUS
OUTPUT
POWER |
APPROX.
WEIGHT
(LB) |
SIZE
(H x W x L)
(INCHES) |
| GS1.5K3/6-600 (120/208) |
120/208 |
60 |
1.5 KVA |
C/F |
C/F |
| GS1.5K3/5-600 (220/380) |
220/380 |
50 |
1.5 KVA |
C/F |
C/F |
| GS1.5K3/4-600 (115/200) |
115/200 |
400 |
1.5 KVA |
C/F |
C/F |
| GH3K3/6-600 (120/208) |
120/208 |
60 |
3 KVA |
C/F |
C/F |
| GH3K3/5-600 (220/380) |
220/380 |
50 |
3 KVA |
C/F |
C/F |
| GH3K3/4-600 (115/200) |
115/200 |
400 |
3 KVA |
C/F |
C/F |
|
GH4.5K3/6-600 (120/208) |
120/208 |
60 |
4.5 KVA |
C/F |
C/F |
|
GH4.5K3/5-600 (220/380) |
220/380 |
50 |
4.5 KVA |
C/F |
C/F |
|
GH4.5K3/4-600 (115/200) |
115/200 |
400 |
4.5 KVA |
C/F |
C/F |
| GH6K3/6-600
(120/208) |
120/208 |
60 |
6 KVA |
C/F |
C/F |
| GH6K3/5-600
(220/380) |
220/380 |
50 |
6 KVA |
C/F |
C/F |
| GH6K3/4-600
(115/200) |
115/200 |
400 |
6 KVA |
C/F |
C/F |
| GH9K3/6-600
(120/208) |
120/208 |
60 |
9 KVA |
C/F |
C/F |
| GH9K3/5-600
(220/380) |
220/380 |
50 |
9 KVA |
C/F |
C/F |
| GH9K3/4-600
(115/200) |
115/200 |
400 |
9 KVA |
C/F |
C/F |
|
GH15K3/6-600
(120/208) |
120/208 |
60 |
15
KVA |
C/F |
C/F |
|
GH15K3/5-600
(220/380) |
220/380 |
50 |
15
KVA |
C/F |
C/F |
|
GH15K3/4-600
(115/200) |
115/200 |
400 |
15
KVA |
C/F |
C/F |
|
GH20K3/6-600
(120/208) |
120/208 |
60 |
20 KVA |
C/F |
C/F |
|
GH20K3/5-600
(220/380) |
220/380 |
50 |
20 KVA |
C/F |
C/F |
|
GH20K3/4-600
(115/200) |
115/200 |
400 |
20 KVA |
C/F |
C/F |
|
GH25K3/6-600
(120/208) |
120/208 |
60 |
25 KVA |
C/F |
C/F |
|
GH25K3/5-600
(220/380) |
220/380 |
50 |
25 KVA |
C/F |
C/F |
|
GH25K3/4-600
(115/200) |
115/200 |
400 |
25 KVA |
C/F |
C/F |
|
GH30K3/6-600
(120/208) |
120/208 |
60 |
30 KVA |
C/F |
C/F |
|
GH30K3/5-600
(220/380) |
220/380 |
50 |
30 KVA |
C/F |
C/F |
|
GH30K3/4-600
(115/200) |
115/200 |
400 |
30 KVA |
C/F |
C/F |
|
GH35K3/6-600
(120/280) |
120/280 |
60 |
35 KVA |
C/F |
C/F |
|
GH35K3/5-600
(220/380) |
220/380 |
50 |
35 KVA |
C/F |
C/F |
|
GH35K3/4-600
(115/200) |
115/200 |
400 |
35 KVA |
C/F |
C/F |
*Three-Phase
Inverters: Nova Galaxy Series inverters can be
arranged for three-phase operation by the customer upon request. We accomplish this by
packaging three separate single-phase inverters as one three-phase unit or as a series of
modules. All popular nominal DC input voltages and AC output voltages are available upon
request, in sizes from 1.5-60+ KVA. Please (C/F) consult the factory for details.
Specifications
Electrical
Input Voltage: 600 VDC (Extended range available)
Output Voltage: See Table
Frequency: 50 Hz, 60 Hz, 400 Hz
(+/-0.5%)
Frequency Regulation: +/-0.5% N.L. to F.L.
Voltage Regulation: +/-1.5% N.L. to F.L.
Efficiency: Approximately 80% or higher (depending on model)
Reactive Load: 0.75 Lead to 0.75 Lag
Distortion: 5% THD, 3% Single Harmonic into full resistive load
Overload: 125% for 5 minutes
| Overload Protection Range: |
Automatic overload &
short circuit protection |
| Sync & Phase Lock Range: |
+/-3 Hz, Typical (50/60
Hz models) |
| Transient Response: |
Approx. 1/4 cycle recovery to
95% of nominal |
Environmental & Mechanical
| Operating Temp: |
-20°C to +50°C Standard
-40°C to +71°C Optional |
Cooling: By internal DC fan
Vibration: Normal shipping and handling
Shock: 20g, 11 mS half sinewave (shock mounts available severe
enviroments)
Humidity: To 95% RH non-condensing
| EMI: |
Designed to meet FCC Part 15,
Class A, Can
meet MIL-STD-461 with additional filtering |
Applications
- Work Trains
- Trolleys
- Mass Transit Stationary
Standard Features
- Pure Sinewave Output
- Internal Transient Suppression Filter Network for input voltage
transients
- High reliability, MTBF exceeds 100,000 hours (held data)
- OV, O.L. and O.T. protected
- MTTR below 30 minutes; modular design
- Withstands high reactive load
- Tight voltage and frequency regulation
- Boards are conformal coated
- Input Circuit Breaker (optional on 15kVA and above)
Available Options
- Ruggedized to meet MIL-STD-810 shock,
vibration and humidity ("R" option)
- Wide temperature range -40°C to +71°C (with derating)
- Special output voltages and frequencies
- MS Connectors or outlets (rack mount models only)
- Custom painting and marking
- Handles (rack mount models only)
- High inrush for motor start
- Transfer switch to alternate AC source
- Chassis slides (rack mount models only)
- Switchable 50/60 Hz output
- Output fault alarm (relay closure)
EXPERIENCE COUNTS! Our experience in this field is the most valuable resource we offer to
our customers. Nova's 600 VDC and 750 VDC inverters are currently being used throughout
the world in the most demanding Mass Transit applications. Some of the projects we've
worked on include:
Work Train Applications: Inverters in various sizes, from 5-20
kVA, are currently utilized by such
customers as Amtrack and the MBTA for powering equipment on third rail 450-750 VDC Work
Train Applications. Everything from hand tools to lighting run on Nova inverters. Even
on-board electric toilets are powered by our inverters!
Trolley Applications: Nova has supplied specialized inverters for many custom Trolley
Applications. In addition to our other custom designs, we have designed and built
special inverters modified to accept 900 VDC continuous input at the customer's request.
Nova inverters are also used to power lighting on Historic Trolley Systems across the
country. The next time you see a restored trolley, remember that the lights are probably
powered by Nova!
Subway Applications: Our durable 600 VDC inverters are currently being used by such customers
as Chicago Transit Authority and Long Island Railroad for such various applications as
providing emergency power from the third rail. Quite often, it is cheaper and more
pragmatic to install an inverter in a hut (shed) on a siding than to run AC power from a
distant location.
Custom Applications: Nova offers an almost infinite combination of custom cabinets and
configurations to satisfy almost any application! Mobile applications, as well as outdoor
applications subject to rain, snow, ice, wind, etc. are one of our specialties! Our
inverters are extremely rugged by design, and feature an advanced Internal Suppression
Filter Network to suppress the significant transients usually associated with these
applications. Please don't hesitate to contact the factory for additional information.
Contact us
Visa and MasterCard Accepted
|