1 - 5 KVA LIGHTWEIGHT GALAXY SERIES TRUE ON-LINE UPS

• COMPACT CHASSIS (1U - 5U TALL)
• ULTRA LIGHTWEIGHT DESIGN
• POWER FACTOR CORRECTED UNIVERSAL INPUT
• SNMP COMMUNICATIONS
• LITHIUM IRON PHOSPHATE BATTERIES AVAILABLE

WHEN EVERY POUND COUNTS!

Nova's Lightweight Galaxy-Series UPS Systems are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments in compliance to to MIL-STD-1399, MIL-STD-461, MIL-S-901, MIL-STD-167, MIL-STD-810, MIL-STD-740, and DOD-STD-1399. These models utilize True On-Line technology, offering maximum field-proven reliability for severe environment and high reliability applications such as:

• Military Applications: Including HMMWV, UAV, Shipboard, Submarine, Aircraft, Mobile Power Units, Shelters, Transportable Systems, Tactical Systems, Ground Support, and more.

• Heavy-Duty Industrial Applications

• Demanding Commercial Applications

• Communications Systems


TYPICAL 1U MODEL
Click to Enlarge
Click here for specs (PDF)

TYPICAL 2U MODEL
Click to Enlarge
Click here for specs (PDF)

TYPICAL 3U MODEL
Click to Enlarge
Click here for specs (PDF)

TYPICAL 4U MODEL
Click to Enlarge
Click here for specs (PDF)

TYPICAL 5U MODEL
Click to Enlarge
Click here for specs (PDF)

 

 

 

RUGGED TRUE ON-LINE UPS
rACK MOUNT UPS
GALAXY SERIES
Partial Model Selection

120 VAC OUTPUT MODELS (400 Hz Input and/or Output optional on all models)

MODEL KVA KW NOMINAL INPUT INPUT AMPS UPS LBS. RUNTIME HEIGHT OUTLINE DRAWING
GRSLPFC11-5K60-120/240A-120-5M-5U 5 4 120-240VAC 26A 110 4 min @ 3 kw 5U
GRSLPFC11-5K60-120/240A-120-5M-5U-LIFE 5 4 120-240VAC 26A 75 4 min @ 3 kw 5U
GRSLPFC11-5K60-120/240A-120-4U 5 4 120-240VAC 26A 45 EXTERNAL 4U
GRSLPFC11-3K60-120/240A-120-5M-4U 3 3 120-240VAC 26A 95 5 min. 4U
GRSLPFC11-3K60-120/240A-120-5M-4U-LIFE 3 3 120-240VAC 24/12A 70 5 min. 4U
GRSLPFC11-3K60-120/240A-120-10M-4U 3 2.4 120-240VAC 24/12A 95 7 min. 4U
GRSLPFC11-3K60-120/240A-120-5M-3U 3 2.4 120-240VAC 24/12A 80 5 min. 3U
GRSLPFC11-3K60-120/240A-120-5M-3U-LIFE 3 2.4 120-240VAC 24/12A 65 5 min. 3U
GRSLPFC11-2K60-120/240-120-5M-3U 2 1.6 120-240VAC 16/8A 80 7 min. 3U
GRSLPFC11-2K60-120/240-120-5M-3U-LIFE 2 1.6 120-240VAC 16/8A 65 7 min. 3U
GRSLPFC11-1.5K60-120/240A-120-5M-2U 1.5 1.2 120-240VAC 12/6A 60 5 min. 2U
GRSLPFC11-1.5K60-120/240A-120-10M-2U-LIFE 1.5 1.2 120-240VAC 12/6A 37 10 min. 2U
GRSLPFC11-1K60-120/240A-120-10M-1U-LIFE 0.9 0.7 120-240VAC 8/4A 25 10 min. 1U

230 VAC OUTPUT MODELS (400 Hz Input and/or Output optional on all models)

MODEL KVA KW NOMINAL INPUT AMPS UPS LBS. RUNTIME HEIGHT OUTLINE DRAWING
GRSLPFC11-5K50-120/240A-230-5M-5U 5 4 120-240VAC 26A 110 4 min @ 3 kw 5U
GRSLPFC11-5K60-120/240A-230-5M-5U-LIFE 5 4 120-240VAC 26A 75 4 min @ 3 kw 5U
GRSLPFC11-5K50-120/240A-230-5M-4U 5 4 120-240VAC 26A 45 EXTERNAL 4U
GRSLPFC11-3K50-120/240A-230-5M-4U 3 3 120-240VAC 30/15A 95 5 min. 4U
GRSLPFC11-3K60-120/240A-230-5M-4U-LIFE 3 3 120-240VAC 30/15A 70 5 min. 4U
GRSLPFC11-3K50-120/240A- 230-10M-4U 3 2.4 120-240VAC 24/12A 95 7 min. 4U
GRSLPFC11-3K50-120/240A-230-5M-3U 3 2.4 120-240VAC 24/12A 80 5 min. 3U
GRSLPFC11-3K60-120/240A-230-5M-3U-LIFE 3 2.4 120-240VAC 24/12A 65 5 min. 3U
GRSLPFC11-2K50-120/240A-230-5M-3U 2 1.6 120-240VAC 16/8A 80 7 min. 3U
GRSLPFC11-2K50-120/240A-230-5M-3U-LIFE 2 1.6 120-240VAC 16/8A 65 7 min. 3U
GRSLPFC11-1.5K50-120/240A-230-5M-2U 1.5 1.2 120-240VAC 12/6A 60 5 min. 2U
GRSLPFC11-1.5K50-120/240A-230-10M-2U-LIFE 1.5 1.2 120-240VAC 12/6A 37 10 min. 2U
GRSLPFC11-1K50-120/240A-230-5M-1U-LIFE 0.9 0.7 120-240VAC 8/4A 25 10 min. 1U

THREE-PHASE INPUT MODELS (400 Hz Input and/or Output optional on all models)

MODEL KVA KW NOMINAL INPUT AMPS UPS LBS. RUN TIME HEIGHT OUTLINE DRAWING
GRSLPFC11-5K60-120/208-120-5M-5U 5 4 120/208VACthree-phase 15A 110 4 min @ 3 kw 5U
GRSLPFC11-5K60-120/208-5M-5U-LIFE 5 4 120/208VACthree-phase 15A 75 4 min @ 3 kw 5U
GRSLPFC11-3K60-120/208-120-5M-4U 3 3 120/208VACthree-phase 11A 95 5 min 4U
GRSLPFC11-3K60-120/208-120-5M-4U-LIFE 3 3 120/208VACthree-phase 9A 70 5 min 4U
GRSLPFC11-3K60-120/208-120-10M-4U 3 2.4 120/208VACthree-phase 9A 95 7 min 4U
GRSLPFC11-3K60-120/208-120-5M-3U 3 2.4 120/208VACthree-phase 9A 80 5 min 3U  
GRSLPFC11-3K60-120/208-120-5M-3U-LIFE 3 2.4 120/208VACthree-phase 9A 65 5 min 3U  
GRSLPFC11-2K60-120/208-120-5M-3U 2 1.6 120/208VACthree-phase 6A 80 7 min 3U  
GRSLPFC11-2K60-120/208-120-5M-3U-LIFE 2 1.6 120/208VACthree-phase 6A 65 7 min 3U  
GRSLPFC11-1.5K60-120/208-120-5M-2U 1.5 1.2 120/208VACthree-phase 5A 60 5 min 2U  
GRSLPFC11-1.5K60-120/208-120-5M-2U-LIFE 1.5 1.2 120/208VACthree-phase 5A 37 10 min 2U  

Note: Three-phase input models do not have PFC input

 

OPTIONS

Power distribution units
• Ruggedization against high shock, vibration and humidity
• MS connector mates and multiple output outlets
• Chassis Slide Guides
• Electromechanical transfer switch.
• Additional battery back-up time
• Custom Enclosures
• Additional run time via external batteries
• 3Ø Power Input
• Premium VRLA batteries with up to 10 year life
• 400 Hz input and / or output
• “LIFE” models feature internal Lithium Iron Phosphate batteries for substantial weight savings and longer runtime, including embedded Battery Management System
• CAD Free Connectors
• Non-PVC wiring
• 28 VDC Input
• High IP Protection for front / rear panels
• AUX DC Outputs
RTCA/DO-160G Compliant Aircraft Grade Package

 

SPECIFICATIONS

ELECTRICAL

Input Voltage: 120/240 VAC Autoselect PFC (3Ø
input optional)
Output Voltage: 120, 208, or 230 VAC (specify)
Frequency: 50 / 60 / 400 Hz. Available
Voltage Regulation: ± 2% NL to FL
Frequency Regulation: ± 0.5% NL to FL
Harmonic Distortion: 5% THD, 3% typical  
Input Power Factor: 0.95 or Better @ half-full load
Efficiency at full load: 80-85% @ full load typical (batteries charged)
Connections: MS Connector (mates opt.)

NOMINAL DIMENSIONS:

UPS Dimensions:
19" Wide x 24" Deep (See chart for height)

External Battery Dimensions (5KVA EXT Models):
5.25 high x 19” wide x 24” deep Outline Drawing

Note: External batteries available on all models if increased run time is required – up to 24 hours.

INTERNAL BATTERIES

Internal on all but 5KVA EXT models

• Standard sealed, maintenance free lead acid batteries have -20 to +50C operating range and useful life of 8-10 years @ +25C ambient.
• Optional Premium sealed, maintenance free lead acid batteries have -40 to +80C operating range and useful life of 8-12 years @ +25C ambient.
• Optional Lithium Iron Phosphate batteries (as shown in units with “LiFe” model suffix) have -20 to +50C operating range and useful life of 8-10 years @ +25C ambient, but are much lighter than lead acid batteries and offer about twice the battery run time.

PROTECTIVE FEATURES

AC & DC Input Circuit Breakers, Low Battery
Shut Off, Overload & Thermal Protected, Input
Under/Overvoltage Protected, Audible Alarm with
Silence Switch.

ENVIRONMENTAL

UPS Operating Temp.: -20° to +55°C (Extended ranges optional)
UPS Storage temperature range: -40° to +71°C (Electronics Only - Extended ranges optional)
Humidity: to 95% RH non-condensing – Designed to meet MIL-STD-810 optionally. All boards conformal coated with Acrylic MIL-I-46058 Type R.
Elevation: 15,000 Ft. (4,572m) operating;
40,000 ft. (12,192m) non-operating (higher optional)
Shock: 20g, 11 mS half sinewave – Designed to meet MIL-STD-810
Audible Noise: Less than 55 dbA at 5 ft.
Battery Storage Temperature Range:
-20° to +50°C (Standard)
-40° to +80° C (Optional) Using premium VRLA batteries.

Note: Run time shown using standard batteries. Consult Factory for run times using premium batteries. For best results, batteries must be kept at 25 degrees Celsius ambient temperature. Extreme low temperatures will result in reduced run time, while extreme high temperatures result in significantly reduced battery lifespan. Click here for more information on THE EFFECTS OF EXTREME TEMPERATURES ON BATTERIES.

MTBF: 100,000+ hours per field data @ +25C Ambient Ground-Fixed
MTTR: 30 minutes by qualified personnel

STD. REMOTE CONTACTS/COMMUNICATIONS

SNMP V1.0 standard via CAT-5 Connector
Major Alarm: Logic Fault, Low Battery, OT, UPS
Overloaded.
Minor Alarm: Utility Off
RS 232 (Available-Optional) Via DB 9 Connector
Alarm Contacts(Available-Optional)

INDICATORS

Status (Red / Green)
UPS Off (Red)
Logic Fault (Red)
Low Battery (Red)
Over Temperature (Red)
Load on Utility (Red) with optional transfer switch

AUDIBLE

Audible alarm with silence switch

 

SYSTEM COMPLIANCE

MIL-STD-1399 Section 300B: For Type I apparatus

MIL-STD-740-1: Airborne Sound Measurements for Shipboard Equipment

MIL-STD-740-2: Structureborne Vibratory Acceleration Measurements

Additional Ruggedization to meet MIL-S-901, MIL-STD-167, MIL-STD-810, and DOD-STD-1399: The UPS System’s construction is extremely robust, and ruggedized throughout. All components and modules within the unit are mounted using additional steel brackets and heavy-duty stainless-steel hardware, which is then further secured using Loctite and RTV where required. All boards are conformal-coated (Acrylic MIL-I-46058 Type R) for maximum resistance to potential condensation and fungus growth. The unit was tested and qualified as follows:

MIL-S-901D for Grade A, Class II, Type B Equipment (mounted in shock-isolated rack attenuating to 20g/11ms max)
(mounted in shock-isolated rack attenuating to 20g/11ms max)

MIL-STD-167-1 for Type I Equipment

MIL-STD-810F:

* Air Temperature per MIL-STD-810F Method 502.4, Procedure II

* Operational Humidity per MIL-STD-810F Method 507.4.

* Salt Fog Atmosphere per MIL-STD-810F Method 509.4

* Steady State Temperature per MIL-STD-810F, Method 501.4, Procedure I (Constant Temperature) and Method 502.4, Procedure I

* Temperature Shock per MIL-STD-810F, Method 503.4, Procedure II, Cyclic.

* Storage and Transportation Humidity per MIL-STD-810F, Method 507.4

* Altitude per MIL-STD-810F, Method 500.4, Procedure I, Storage/Air Transport.

* Rapid Decompression per MIL-STD-810F, Method 500.4, Procedure III

* Transit Shock per MIL-STD-810F, Method 516, Procedures IV, V and VI,

* Transportation Vibration per MIL-STD-810F, Method 514.5, Procedure II for loose cargo transportation

* Transit Drop per MIL-STD-810F, Method 516.5, Procedure IV

* Bench Handling per MIL-STD-810F, Method 516.5, Procedure VI

DOD-STD-1399 Section 301A Table V – Design Limits for Ship Motion

Internal EMI Reduction Package to meet MIL-STD-461: The design of this unit is specifically focused on reducing EMI emissions. The UPS contains substantial internal filtering to minimize EMI emissions. Inputs which may be susceptible to transients are protected by several methods. The compact rack mount chassis is specifically treated with low surface resistivity finishes on the interior. All aluminum parts are treated with clear irridite. The steel parts are treated with zinc plate, followed by a clear chromate. Paint method via ANSI-61 gray is designed to assure excellent bonding of mating sheet metal parts. All input and output ventilation filters include metal honeycomb-style or mesh filters. The unit was tested and qualified as follows:

MIL-STD-461E: CE101, CE102, CS101, CS114, CS116, RE102, RS101, and RS103

Note: Qualification testing was performed with optional premium batteries required to meet temperature testing requirements.

OPTIONAL COMPLIANCE WITH RCTA/DO-160G AIRCRAFT GRADE PACKAGE

RTCA/DO-160G Qualified: Tested successfully by Boeing to meet RTCA/DO-160G for:

  • Rapid Decompression: Section 4 Cabin Pressure (8K) to Max Oper Alt (35K) in 15 sec; Hold for 10 min
  • Crash Safety Sustained: Section 7, Cat B - Up = 3.0g - Down = 6.0g - Fwd = 9.0g - Aft = 1.5g - Side =4.0g
  • Explosive Atmosphere: Non-Ignition Test Sec. 9.6.2, Cat E

Qualifications to MIL-STD-810B include:

  • Operating Temperature Shock per MIL-STD-810B Method 503 0 to 71°C
  • Vibration per MIL-STD-810B Method 514.6, Category 12, Procedure I

 

 
 