int_nav.gif

 
 
 
 
 
 

Other Products


Charts/Graphs

SPECS/STD FEATURES
AVAILABLE OPTIONS
  FCU6K-230/400-220
 
Microprocessor Based Design
FREQUENCY CONVERTER
NON ISOLATED OUTPUT (Isolated Transformer Optional)
Converts 230/400VAC, 50/60, 3Phase to 220VAC, 1Phase, 6KVA


The FCU converts various input 3Phase voltages of 120/208 50/60Hz or 230/400V 50/60Hz to single Phase 220V, 50, 60 or 400 Hz(specify output frequency). It can be used in test systems where the input frequency and voltage are not suitable, or in places where 3 Phase power is available in abundance, but single phase power is very limited. The unit is particularly suitable for apparatus that requires a 400Hz source, such as airborne or shipboard systems.

NOVA's Frequency Converter unit (FCU) provides non isolated output (from the input), however an external transformer can be optionally supplied to provide the necessary isolation. The unit is capable of sustaining reactive load up to power factor of 75%, or non linear loads (e.g. switching power supplies) with power requirement of 3KW maximum.

 

 




• Portable, compact, and light weight.
• Metered output voltage and current.
• Stable a output frequency within + .5%.
• Regulated output within + 2%.
• OL and OT protection.
• Input circular connector.
• Terminal ports for output quick connection.
• Balanced input current.
• Low output harmonic distortion.
• Rugged construction.
• Output Voltage Adjustment ± 10%

• Ruggedization against shock, vibration and humidity to MIL-STD-810
MS Connector for Output.
Elapse Time Meter.

 



Input:
220/400V 3 Phase (Specify Delta or Wye)
Output: 230 V Single Phase.
Frequency: 50, 60, or 400 Hz (specify).
Voltage Regulation: + 2% NL to FL.
Frequency Regulation: + 0.5%
Harmonic Distortion: 5% THD, 3% SHD.
Power Factor: 0.7 lead to 0.7 lag.
Efficiency at full load: 90% typical.
Overload: 125% for 5 minutes.
MTBF: Over 30,000 Hours per MIL-HDBU 217
MTBR: 30 Minutes.


Standard Indicators: Input, Output, Overload and Over temperatureOutput Voltage and Current Meters.
Protective Features:Current Limit, Short Circuit Protection, Thermal Protection. Operating Temperature: -20 ºC to 50 ºC
Storage Temperature Range: -40 ºC to + 85 ºC
Humidity: to 95% non-condensing
Elevation: 15,000 Ft. (4.572m) operating; 40,000 ft (12.192m) non-operating.
Shock: 20g 11ms half sinewave.
Audible Noise: Less than 55 dBA at 5 ft.
Size: 12.50" (W) x 17" (D) x 9" (H)
Color: Off white panel
Weight: 47 lb.

 


ease click here to request more information on this product.
 
 