int_nav.gif

 
 
 
 
 
 

Other Products


Charts/Graphs

MODEL SELECTION
SPECS/STD FEATURES
AVAILABLE OPTIONS
  GALAXY SERIES
 
FREQUENCY CONVERTER
500 VA - 30 KVA
for demanding 50 Hz, 60 Hz, and 400 Hz applications


Nova frequency converters are high-reliability power sources specifically designed for demanding applications in high shock, vibration, humidity, and EMI environments. They can be built to meet MIL-STD-810, MIL-STD-1399, MIL-STD-1472, MIL-STD-461, and other standards optionally. They are suitable for severe environment and high reliability applications such as:

MILITARY APPLICATIONS: HMMWV, UAV,
Shipboard, Submarine, Aircraft and Mobile Power Units, Shelters
Aircraft Power
AC Power from vehicle battery
Communications Systems
Cellular Sites
European Power / Export Testing
Power Conditioning & Frequency Stabilization
U.S. Power Abroad
Railroad Signaling Power

 

 

Partial Standard Model Selection

(Consult factory foradditional models)

PRODUCT
SPEC.
PARTIAL
MODEL NO.
KVA
OUTPUT
VOLTAGE
OUTPUT
FREQ
(HZ.)
WEIGHT
(LBS)
H"
W"
D"
GHFC1K50
GHFC 1K60
GHFC1K400
1
220
117
115
50
60
400
200
175
150
24.0
20.75
7.15
GHFC2K50
GHFC2K60
GHFC2K400
2
220
117
115
50
60
400

350
275
250

30.0
24.0
8.50
GHFC3K50
GHFC3K60
GHFC3K400
3
220
117
115
50
60
400
350
320
350
30.0
24.0
8.50
GHFC5K50
GHFC5K60
GHFC5K400
5
220
117
115
50
60
400
410
380
350
30.0
26.0
11.0
GHFC7.5K50
GHFC7.5K60
GHFC7.5K400
7.5
220
117
115
50
60
400
445
425
400
30.0
36.0
17.0
GHFC10K50
GHFC10K60
GHFC10K400
10
220
117
115
50
60
400
470
450
425
36.0
36.0
17.0
GHFC15K50
GHFC15K60
GHFC15K400
15
220
117
115
50
60
400
550
525
400
36.0
36.0
17.0
GHFC20K50
GHFC20K60
GHFC20K400
20
220
117
115
50
60
400
C/F
C/F
C/F
C/F
GHFC25K50
GHFC25K60
GHFC25K400
25
220
117
115
50
60
400
C/F
C/F
C/F
C/F
GHFC30K50
GHFC30K60
GHFC30K400
30
220
117
115
50
60
400
C/F
C/F
C/F
C/F

BACK TO TOP




• Solid-State Design
• Advanced Modular Capabilities
• Pure Sinewave Output
• Lightweight, extremely compact enclosures
• High reliability
• OV, O.L. and O.T. protected
• MTTR below 30 minutes; modular design
• Withstands high reactive load
• Tight voltage and frequency regulation
• Boards are conformal coated

• Power Factor correction available on selected GLFC-Series models.
Ruggedization to meet MIL-STD-810 shock,
vibration and humidity
Wide temperature range -40°C to +71°C
Special output voltages and frequencies
MS Connectors or outlets
Custom painting and marking
Heavy-Duty Handles
High inrush for motor start
Wall Mount Plate
Custom NEMA Wall-Mount or Floor-Mount Enclosures
Frequency Meters
Elapsed Time Meter
Alarm Contact Closures
Remote Start / Stop Control
Output Circuit Breaker
Crystal Frequency Control
Contacts for Remote Operation
Dual Output
Safety Door Locks (Cabinet Models)
+/- 10% Output Voltage Adjustment (located on front door of Cabinet Models)
Heavy Duty Casters (Cabinet Models)

* Some options listed above may not fit or may already be standard equipment on some Nova Frequency Converters. Please consult the factory for details.

 

 



Power Ratings: 120 VA - 30+ KVA

Input Voltage: Most standard AC voltages including 115, 120, 200, 208, 220, 240, 277, 380, and 480 available in single and three-phase configurations. Power Factor correction available on selected GLFC-Series models.
Output Voltage: Most standard AC voltages including 115, 120, 200, 208, 220, 240, 277, 380, and 480 available in single and three-phase configurations.
|Frequency: 50 Hz, 60 Hz, or 400 Hz (+/-0.5%)
Frequency Regulation: +/-0.5% N.L. to F.L. (Crystal available)
Frequency Transients: None
Voltage Regulation:
+/-1.5% N.L. to F.L.
Efficiency: Approximately 85-95% (depending on model)
Total Harmonic Distortion: 3% Typical, 5% Max
Overload: 120% Typical Power Factor: 0.7 Lead to 0.7 Lag
Input Circuit Protection: Circuit Breaker / Fuses, Transient Suppressors Output
Circuit Protection:
Current Limit, Short Circuit Protection, Thermal Protection, and Semi-Conductor Protection



Operating Temp:
-20°C to +50°C Standard
-40°C to +71°C Optional
Cooling: Forced Air by internal DC brushless fan
Vibration: Normal shipping and handling
Shock: 20g, 11 mS half sinewave – Designed to meet MIL-STD-810 optionally
Elevation: 10,000 ft. typical
Humidity: to 95% RH non-condensing – Designed to meet MIL-STD-810. All boards conformal coated with Acrylic MIL-I-46058 Type R.
Audible Noise: 65 dBA at 5 ft. typical
EMI: Designed to meet FCC Part 15, Class A. Designed to meet MIL-STD-461 with optional additional filtering.
MTBF:30,000+ hours typical per MIL-MDBK-217
MTTR: Less than 30 minutes.



Please click here to request more information on this product.
 
 
Untitled Document