int_nav.gif

 
 
 
 
 
 

Other Products


Charts/Graphs

60 HZ MODELS
50 HZ MODELS
400 HZ MODELS
3 PHASE MODELS
SPECS/STD FEATURES
AVAILABLE OPTIONS
  RUGGED, LIGHTWEIGHT INVERTERS
 
72 VDC Nominal Input
GALAXY SERIES


Utilizing field proven technology, this family of rugged
pure sinewave DC-AC Inverters is suitable for harsh
environments and can be customized for unique
applications including:

• Military programs • AC Power from battery
• Communications • HMMWV applications
• Cellular sites • TV & Radio vans
• Shelters • Shipboard applications
• SATCOM terminal • Rapid transit & Rail Applications






To download a brochure, please click here

To download the Outline Drawing, please click here

 

 

62-84 VDC Operating Input / 300 VA – 1.5KVA
(Consult factory for higher power ratings)

PARTIAL STANDARD PRODUCT LISTING

60 HZ MODELS

MODELS OUTPUT VAC OUTPUT FREQUENCY CONTINUOUS OUTPUT POWER WEIGHT SIZE
NGL3060-72-120
120
60 Hz
300 VA / 240 W
6 LB.
3.25 x 5 x 13.75
NGL1K60-72-120
120
60 Hz
1000 VA / 800 W
6 LB.
3.25 x 5 x 13.75
NGL1.5K60-72-120
120
60 Hz
1500 VA / 1200 W
6 LB.
3.25 x 5 x 13.75

BACK TO TOP

 

50 HZ MODELS

MODELS OUTPUT VAC OUTPUT FREQUENCY CONTINUOUS OUTPUT POWER WEIGHT SIZE
NGL3050-72-220
220
50 Hz
300 VA / 240 W
6 LB.
3.25 x 5 x 13.75
NGL1K50-72-220
220
50 Hz
1000 VA / 800 W
6 LB.
3.25 x 5 x 13.75
NGL1.5K50-72-220
220
50 Hz
1500 VA / 1200 W
6 LB.
3.25 x 5 x 13.75

BACK TO TOP

 

400 HZ MODELS

MODELS OUTPUT VAC OUTPUT FREQUENCY CONTINUOUS OUTPUT POWER WEIGHT SIZE
NGL30400-72-115
115
400 Hz
300 VA / 240 W
6 LB.
3.25 x 5 x 13.75
NGL1K400-72-115
115
400 Hz
1000 VA / 800 W
6 LB.
3.25 x 5 x 13.75
NGL1.5K400-72-115
115
400 Hz
1500 VA / 1200 W
6 LB.
3.25 x 5 x 13.75

BACK TO TOP



BACK TO TOP



• Pure Sinewave Output
• Compact Size
• Light Weight design
• Extremely Rugged Construction
• High reliability: MTBF exceeds 100,000 hours
• OV, O.L. and O.T. protected
• MTTR below 30 minutes
• Withstands highly reactive load
• Tight voltage and frequency regulation
• Conformal coated boards

Ruggedized to meet MIL-STD-810 shock,
vibration and humidity
Wide temperature range
Special output voltages and frequencies
Provision for 3 Phase connection
with 2 more identical units
19" Panel mount
MS Connectors or outlets
Custom painting and marking
Handles
High inrush for motor start
Transfer switch to alternate AC source
Wall mount plate
• Rail output voltages & frequencies (91.66, 100, 250 Hz)
• Customized VDC input ranges

 



Electrical
Input Voltage:
See chart above
Output Voltage:
See chart above
Frequency: 50 Hz, 60 Hz, 400 Hz (+/-0.5%)
Frequency Regulation:
+/-0.5% N.L. to F.L.
Voltage Regulation:
+/-1.5% N.L. to F.L.
Efficiency:
Approximately 80% (depending on model)
Reactive Load:
0.75 Lead to 0.75 Lag
Distortion:
5% THD, 3% Single Harmonic
Overload:
125% for 5 minutes

Overload Protection Range: Automatic overload & short circuit protection
Isolation: 1500 Volt
Transient Response: Approx. 3 cycle recovery to 95% of nominal




Operating Temp: -20°C to +50°C Std
-30°C to +60°C Optional
Storage Temp: -40°C to +71°C
Cooling: By internal DC brushless fan
Vibration: Normal shipping and handling
Shock: 20g, 11 mS half sinewave
Humidity: To 95% RH non-condensing
EMI: Designed to meet FCC Part 15, Class A; can meet MIL-STD-461 with optional filtering


DC-AC INVERTER FAQ

Please click here to request more information on this product.

 
Untitled Document