int_nav.gif

 
 
 
 
 
 

Other Products


Charts/Graphs

60 HZ MODELS
50 HZ MODELS
3 PHASE MODELS
SPECS/STD FEATURES
AVAILABLE OPTIONS

 

  JUPITER SERIES
 
RUGGED, LIGHTWEIGHT
INVERTERS

120 VDC Nominal Input / Pure Sine-Wave Output


• Military programs, vehicular, shipboard
• AC Power from vehicle battery
• Communications
• Shelters
• Utility Applications

 

105-150 VDC Operating Input / 10 KVA - 50 KVA
(Consult factory for higher power ratings)

60 HZ MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

OUTLINE DRAWING
(PDF)
60 HZ
MODELS
OUTPUT
VAC
OUTPUT
FREQ(HZ)
CONTINUOUS
OUTPUT
POWER
APPROX.
WEIGHT(LB)
SIZE
(HxWxL) INCHES
J10K60-120
120
60
10 KVA / 8 KW
750
63.00x22.00x31.5
J15K60-120
120
60
15 KVA / 12 KW
800
63.00x22.00x31.5
J20K60-120
120
60
20KVA / 16 KW
840
63.00x22.00x31.5
J30K60-120
120
60
30KVA / 24 KW
950
63.00x44.00x31.5

BACK TO TOP


50 HZ MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

OUTLINE DRAWING
(PDF)
50 HZ
MODELS
OUTPUT
VAC
OUTPUT
FREQ(HZ)
CONTINUOUS
OUPUT
POWER
APPROX.
WEIGHT(LB)
SIZE
(HxWxL) INCHES
J10K50-120(220)
220
50
10 KVA / 8 KW
750
63.00x22.00x31.5
J15K50-120(220)
220
50
15 KVA / 12 KW
800
63.00x22.00x31.5
J20K50-120(220)
220
50
20KVA / 16 KW
840
63.00x22.00x31.5
 
J30K50-120(220)
220
50
30KVA / 24 KW
950
63.00x44.00x31.5

BACK TO TOP

 


50 + 60HZ 3 PHASE MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

3-PHASE
MODELS
OUTPUT
VAC
OUTPUT
FREQ
(Hz)
CONTINUOUS
OUTPUT
POWER
APPROX.
WEIGHT
(LB)
SIZE
(H x W x L)
(INCHES)
J10K3/6-120 (120/208)
120/208
60
10KVA / 8KW
770
J10K3/5-120 (220/380)
220/380
50
10KVA / 8KW
790
63x22x31.5
J20K3/6-120 (120/208)
120/208
60
20KVA / 16KW
880
J20K3/5-120 (220/380)
220/380
50
20KVA / 16KW
900
63x22x31.5
J30K3/6-120 (120/208)
120/208
60
30KVA / 24KW
1540
63x43.5x31.5
J30K3/5-120 (220/380)
220/380
50
30KVA / 24KW
1580
63x43.5x31.5
J40K3/6-120(120/208)
120/208
60
40KVA / 32KW
1650
63x43.5x31.5
J40K3/5-120(220/380)
220/380
50
40KVA/ 32KW
1690
63x43.5x31.5
J50K3/6-120 (120/208)
120/208
60
50KVA / 40KW
1760
63x43.5x31.5
J50K3/5-120 (220/380)
220/380
50
50KVA / 40KW
1870
63x43.5x31.5
J60K3/6-120 (120/208)
120/208
60
60KVA / 48KW
2420
63x87x31.5
J60K3/5-120 (220/380)
220/380
50
60KVA / 48KW
2520
63x87x31.5
J80K3/6-120 (120/208)
120/208
60
80KVA / 64KW
3080
63x87x31.5
J80K3/5-120 (220/380)
220/380
50
80KVA / 64KW
3180
63x87x31.5
J100K3/6-120 (120/208)
120/208
60
100KVA / 80KW
3520
63x87x31.5
J100K3/5-120 (220/380)
220/380
50
100KVA / 80KW
3660
63x87x31.5



BACK TO TOP



• Complete input to output ‘Galvanic’ isolation.
• High frequency almost silent operation
• Push button starting and stopping
• Diagnostic panel with LCD and LED display
• Soft start on inverter
• Overload & and short proof on and inverter
• True on-line Operation
• Optional Solid state transfer switch built in
• Optional Maintenance bypass switch built in
• All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance
• FCC class A approved
• Remote isolated dry relay contacts
• Available options to meet military specs, including MIL-STD-461, MIL-STD-167, MIL-STD-810


MONITORING FEATURES


The Inverter includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor in real time the three phase information related to the UPS output and any abnormal conditions that have occurred. Standard commercially available software is provided. The RS232 Feature is included at no additional charge.

Front Panel LCD display and LED indicators.

This will report all Inverter parameters. These includes input and output voltages, currents, frequency, DC voltage and current, as well as many other functions.

LCD Display.

Real time status, data or historical events are displayed and the LCD display. The Inverter parameters, real time clock, inverter, buzzer also can be set through this LCD, The LCD is back lighted by LEDs.

Status LEDs.

A series of LEDs representing all the important information of the Inverter provide information to the user. These LEDs are especially important when abnormal conditions occur. LED descriptions are as follows:

INVERTER ON - Inverter is running normally.

INVERTER SS - Inverter static switch is on while the reserve static switch is opened (off).

SHORT CIRCUIT – Inverter output is in short circuit state.

FUSE / OVERTEMP SD – Inverter has shutdown due to either fuse open or the temperature is too high.

INVERTER FAIL SHUTDOWN – Inverter has shutdown due to inverter AC output voltage too low.

BYPASS ON SHUTDOWN – Inverter shutdown due bypass breaker is closed when the inverter is running.

HIGH DC SHUTDOWN – Inverter shutdown due to DC bus too high when the inverter is running.

OVERLOAD SHUTDOWN – Inverter shutdown due to overload of the inverter for a period greater than the inverter can accept. The inverter will start after 7 seconds.

70% LOAD – load connected to the output is over 70% of the UPS rating.

110% LOAD – load connected to the output is over 110% oh the UPS rating.

125% LOAD - load connected to the output is over 125% of the UPS rating.

150% LOAD – load connected to the output is over 150% of the UPS rating.

RESERVE AC FAIL – reserve AC magnitude is out of range.

RESERVE FREQ FAIL – reserve frequency is out of range.

BATTERY LOW – DC bus (or battery) is lower than 108VDC, low battery shutdown will occur soon.

OTHER OPTIONS

DC INPUT BREAKER OPTION
The optional DC Inout breaker disconnect is offered to provide protection for the input.

SHOCK MOUNT OPTION
The cabinet can be shock mounted, using optional rubber on coil type isolators. This will be enable the unit to withstand shock levels as specified in MIL-STD-901

RUGGEDIZING OPTION
This option will add conformal coating and other additional internal structural members to allow the unit to meet many portions of MIL-STD-810.

TURN ON SERVICE OPTION
We offer a turn on service that will ensure the Inverter has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.

SPARE PARTS KIT OPTION
We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order then if they are ordered later on.

 

BATTERY LOW SHUTDOWN – inverter shutdown due to DC bus (or battery) is lower than approximately 100VDC (lower than the acceptable DC voltage of the inverter).

HIGH DC – DC voltage over 150 VDC

EMERGENCY STOP – Inverter shutdown due to emergency stop switch pushed.

DATA LINE – Blink when data is transmitted to or received from the communication port.

Warning LEDs.

When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are:

RESERVE FAIL – Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range.

FUSE/TEMP - Either inverter fuse is open or over temperature has occurred.

OVERLOAD – Output is overloaded by over 110%, 125% or 150%

HIGH DC – This LED will light as long as the DC voltage is over 140VDC.

BAT LOW – This LED will light when the DC voltage is lower than 108VDC.

BAT LOW STOP – This LED will light when the DC voltage is lower than 100VDC, inverter on is inhibited.

FAULT – The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop.

Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door.

AUDIBLE ALARM – The audible alarm will beep under either one of the following conditions:

INVERTER IS OVERLOADED-
> 110% beep once every 3 seconds
> 125% beep once every second
> 150% beep twice every second

INVERTER IS SHORT CIRCUITED – Beeps continuously

FUSE OPEN
– Beeps continuously

HEAT SINK OVER TEMPERATURE
– Beeps continuously

HIGH DC SHUTDOWN
– Beeps continuously

BYPASS ON STOP
- Beeps continuously

EMERGENCY ON STOP
- Beeps continuously
The buzzer will also beep once every time the inverter is switched on or off to acknowledge to the user that his key entry is valid and accepted.

COMMUNICATIONS OPTIONS
We offer options for communications with this UPS series. Some popular options available at additional cost include the following:

UPSCAN: This is a hand held remote display and control module with LCD and LED display that can monitor via RS-485 UP to 99 UPS Units at a remote distance of up to 3,000 feet.

UPSCALL: This is a modem that will automatically dial out to a specified number when an abnormal situation occurs.

NETAGENT: This provides capability to monitor the UPS over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided by MEGATEC at additional cost.



Specifications for the Nova Jupiter 3 Phase Inverter Series

PHASE
DC Input/ 3-Phase Output
INVERTER  
Output Voltage (VAC)
Please Specify |120/208 |220/380 |230/400 |240/415 |277/480 |120 delta|220 3delta |240 3delta |380 3delta |480 3delta
Wave Form
Sinewave
Output Power Factor
0.7 lead to 0.7 lag
Frequency Lock Range
50 / 60 Hz + 0.1 Hz (crystal controlled)
Output Frequency (free running)
60Hz or 50Hz (please specify)
Phase Shift Under 100% Unbalanced Load
<0.5%
THD (Linear Load)
2% typical 3% max
Overload
<110%
Continuous
110-125%
15 minutes
125-150%
10 minutes
>150%
1 minute
Efficiency (100% Load)
89%
STATIC SWITCH (optional)  
Voltage Range
Same as AC output. (Different voltages are available upon request)
Mains <-> Inverter
0 ms (True Online)
Audible Noise
< 65dBA (at 1m)
Temperature
0-50ºC (32-122ºF) (Other ranges available)
Humidity
0%-90% (Non-condensing)
Altitude
Up to 1500 m Above Sea Level
EN50091-1, -2
Yes
Short Circuit Protection
Yes
Lightning / EMC Filter
MOV / Input & Output ( FCC CLASS A)
Galvanic Isolation
Output True Galvanic Isolation
LED, LCD, Audible Alarm
Yes
Remote Control / Communication Interface
Monitoring 1~99 Units simultaneously / Dry Contact, RS-232, RS-485 (Optional)

DC-AC INVERTER FAQ

Please click here to request more information on this product.

 
 
Untitled Document