int_nav.gif

 
 
 
 
 
 

Other Products


Charts/Graphs

60 HZ MODELS
50 HZ MODELS
3 PHASE MODELS
SPECS/STD FEATURES
AVAILABLE OPTIONS

 

 
  JUPITER SERIES
RUGGED, LIGHTWEIGHT
INVERTERS

120 VDC Nominal Input / Pure Sine-Wave Output


Nova's Jupiter-Series DC-AC Inverters are high-reliability pure sinewave power sources specifically designed for demanding commercial, heavy industrial, and military applications.

They can be built to meet MIL-STD-810, MIL-S-901, MIL-STD-461, and other standards optionally.

These models utilize the most durable components, offering maximum field-proven reliability for severe environment and high reliability applications such as utility stations, shelters, shore power, and communications.

Typical Jupiter 43.5 cabinet with optional shock mounts shown

Click to Enlarge

To download a brochure, please click here

 


105-150 VDC Operating Input / 10 KVA - 50 KVA
(Consult factory for higher power ratings)


60 HZ SINGLE PHASE MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

OUTLINE
DRAWING (PDF)

MODELS

OUTPUT
VAC

OUTPUT FREQ.

CONTINOUS
OUTPUT POWER

WEIGHT

SIZE
(H"x W"x L")

J10K60- 120
120
60 Hz
10 KVA/ 8 KW
770Lbs.
63 x 22 x 31.5
J15K60- 120
120
60 Hz
15 KVA/ 12KW
880Lbs.
63 x 22 x 31.5
J20K60- 120
120
60 Hz
20 KVA/ 16 KW
880Lbs.
63 x 22 x 31.5
J30K60- 120
120
60 Hz
30 KVA/ 24 KW
1650Lbs.
63 x 43.5 x 31.5
J40K60- 120
120
60 Hz
40 KVA/ 32 KW
1760Lbs.
63 x 43.5 x 31.5
J50K60- 120
120
60 Hz
50 KVA/ 40 KW
1870Lbs.
63 x 43.5 x 31.5
J60K60- 120
120
60 Hz
60 KVA/ 48 KW
2420Lbs.
63 x 87 x 31.5
J80K60- 120
120
60 Hz
80 KVA/ 64 KW
3080Lbs.
63 x 87 x 31.5
J100K60- 120
120
60 Hz
100 KVA/ 80 KW
3520Lbs.
63 x 87 x 31.5


BACK TO TOP

50 HZ MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

OUTLINE
DRAWING (PDF)

60HZ SINGLE PHASE MODELS

OUTPUTVAC

OUTPUT FREQ.

CONTINOUS
OUTPUT POWER

WEIGHT

SIZE
(H"x W"x L")

J10K60-120(220)
220
50 Hz
10 KVA/ 8 KW
770Lbs.
63 x 22 x 31.5
J15K60-120(220)
220
50 Hz
15 KVA/ 12KW
880Lbs.
63 x 22 x 31.5
J20K60-120(220)
220
50 Hz
20 KVA/ 16 KW
880Lbs.
63 x 22 x 31.5
J30K60-120(220)
220
50 Hz
30 KVA/ 24 KW
1650Lbs.
63 x 43.5 x 31.5
J40K60-120(220)
220
50 Hz
40 KVA/ 32 KW
1760Lbs.
63 x 43.5 x 31.5
J50K60-120(220)
220
50 Hz
50 KVA/ 40 KW
1870Lbs.
63 x 43.5 x 31.5
J60K60-120(220)
220
50 Hz
60 KVA/ 48 KW
2420Lbs.
63 x 87 x 31.5
J80K60-120(220)
220
50 Hz
80 KVA/ 64 KW
3080Lbs.
63 x 87 x 31.5
J100K60-120(220)
220
50 Hz
100 KVA/ 80 KW
3520Lbs.
63 x 87 x 31.5


BACK TO TOP

 

400 HZ SINGLE PHASE MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

OUTLINE
DRAWING (PDF)

400 HZ MODELS

OUTPUTVAC

OUTPUT FREQ.

CONTINOUS
OUTPUT POWER

WEIGHT

SIZE
(H"x W"x L")

J10K400-120
115
400Hz
10 KVA/ 8 KW
770Lbs.
63 x 22 x 31.5
J15K400-120
115
400Hz
15 KVA/ 12KW
880Lbs.
63 x 22 x 31.5
J20K400-120
115
400Hz
20 KVA/ 16 KW
880Lbs.
63 x 22 x 31.5
J30K400-120
115
400Hz
30 KVA/ 24 KW
1650Lbs.
63 x 43.5 x 31.5
J40K400-120
115
400Hz
40 KVA/ 32 KW
1760Lbs.
63 x 43.5 x 31.5
J50K400-120
115
400Hz
50 KVA/ 40 KW
1870Lbs.
63 x 43.5 x 31.5
J60K400-120
115
400Hz
60 KVA/ 48 KW
2420Lbs.
63 x 87 x 31.5
J80K400-120
115
400Hz
80 KVA/ 64 KW
3080Lbs.
63 x 87 x 31.5
J100K400-120
115
400Hz
100 KVA/ 80 KW
3520Lbs.
63 x 87 x 31.5

 


BACK TO TOP

50 + 60, +400HZ 3 PHASE MODELS
Available with and without Input Circuit Breaker and/or Solid State Transfer Switch

3-PHASE
MODELS
OUTPUT
VAC
OUTPUT
FREQ
(Hz)
CONTINUOUS
OUTPUT
POWER
APPROX.
WEIGHT
(LB)
SIZE
(H x W x L)
(INCHES)
J10K3/6-120 (120/208)
120/208
60
10KVA / 8KW
770
J10K3/5-120 (220/380)
220/380
50
10KVA / 8KW
770
J10K3/4-120 (115/200)
115/200
400
10KVA / 8KW
770
J20K3/6-120 (120/208)
120/208
60
20KVA / 16KW
880
J20K3/5-120 (220/380)
220/380
50
20KVA / 16KW
880
J20K3/4-120 (115/200)
115/200
400
20KVA / 16KW
880
J30K3/6-120 (120/208)
120/208
60
30KVA / 24KW
1650
J30K3/5-120 (220/380)
220/380
50
30KVA / 24KW
1650
J30K3/4-120 (115/200)
115/200
400
30KVA / 24KW
1650
J40K3/6-120(120/208)
120/208
60
40KVA / 32KW
1760
J40K3/5-120(220/380)
220/380
50
40KVA/ 32KW
1760
J40K3/4-120 (115/200)
115/200
400
40KVA/ 32KW
1760
J50K3/6-120 (120/208)
120/208
60
50KVA / 40KW
1870
J50K3/5-120 (220/380)
220/380
50
50KVA / 40KW
1870
J50K3/4-120 (115/200)
115/200
400
50KVA / 40KW
1870
J60K3/6-120 (120/208)
120/208
60
60KVA / 48KW
2420
J60K3/5-120 (220/380)
220/380
50
60KVA / 48KW
2420
J60K3/4-120 (115/200)
115/200
400
60KVA / 48KW
2420
J80K3/6-120 (120/208)
120/208
60
80KVA / 64KW
3080
J80K3/5-120 (220/380)
220/380
50
80KVA / 64KW
3080
J80K3/4-120 (115/200)
115/200
400
80KVA / 64KW
3080
J100K3/6-120 (120/208)
120/208
60
100KVA / 80KW
3520
J100K3/5-120 (220/380)
220/380
50
100KVA / 80KW
3520
J100K3/4-120 (115/200)
115/200
400
100KVA / 80KW
3520


BACK TO TOP

 

STANDARD FEATURES

• Complete input to output ‘Galvanic’ isolation.
• High frequency almost silent operation
• Push button starting and stopping
• Diagnostic panel with LCD and LED display
• Soft start on inverter
•Overload & and short circuit protection on charger and inverter
• True on-line Operation
• Optional Solid state transfer switch built in
• Optional Maintenance bypass switch built in
• All electronics are built in modular front access and front removable sub assemblies for easy service and maintenance
• FCC class A approved
• Remote isolated dry relay contacts
• Available options to meet military specs, including MIL-STD-461, MIL-STD-167, MIL-STD-810


MONITORING FEATURES


The unit includes an RS232 communication option called UPSCOM. This is an RS232 connection to a PC that can monitor the output parameters and any abnormal conditions that have occurred in real time. Standard commercially available software is required. The RS232 Feature is included at no additional charge.

FRONT PANEL LCD DISPLAY AND LED INDICATORS

This will report all Inverter parameters including input and output voltages, currents, frequency, battery voltage, battery current, and many other functions.

LCD DISPLAY

Real time status, data, and historical events are displayed via the LCD display. The UPS parameters, real-time clock, inverter, and buzzer can also be set through this LCD, which is backlit by LEDs for visual clarity.

STATUS LEDs

LEDs representing all important operational information provide feedback to the user. LED descriptions are as follows:

INVERTER ON - Inverter is running normally.

INVERTER SS - Inverter static switch is on while the reserve static switch is opened (off).

SHORT CIRCUIT – Inverter output is in short circuit state.

FUSE / OVERTEMP SD – Inverter has shut down due to either fuse open or overtemperature.

INVERTER FAIL SHUTDOWN – Inverter has shut down due to low inverter AC output voltage.

BYPASS ON SHUTDOWN – Inverter shut down due to closed bypass breaker.

nverter shut down due closed bypass breaker (while inverter running).

HIGH DC SHUTDOWN – Inverter shut down due to high DC bus.

OVERLOAD SHUTDOWN – Inverter shutdown due to overload of the inverter for a period greater than the inverter can accept. The inverter will start after 7 seconds.
70% LOAD – load connected to the output is over 70% of the Inverter rating.
110% LOAD – load connected to the output is over 110% oh the Inverter rating.
125% LOAD - load connected to the output is over 125% of the Inverter rating.
150% LOAD – load connected to the output is over 150% of the Inverter rating.

RESERVE AC FAIL – reserve AC magnitude is out of range.

RESERVE FREQ FAIL – reserve frequency is out of range.

BATTERY LOW – DC bus (or battery) is lower than specified range, low battery shutdown will occur soon.

BATTERY LOW SHUTDOWN – inverter shutdown due to DC bus (or battery) lower than the acceptable DC voltage of the inverter.

HIGH DC – DC voltage over the acceptable DC voltage of the inverter.

EMERGENCY STOP – Inverter shut down activated by emergency stop switch.

DATA LINE – Blink when data is transmitted to or received from the communication port

 

OTHER OPTIONS

CASTERS & LEVELERS
For portability, the 22" wide Jupiter cabinets may be optionally equipped with the base-mounted caster / leveler set as shown here.

DC INPUT BREAKER OPTION
The optional DC Inout breaker disconnect is offered to provide protection for the input.

SHOCK MOUNT OPTION
The cabinet can be shock mounted, using optional rubber on coil type isolators. This will be enable the unit to withstand shock levels as specified in MIL-S-901

RUGGEDIZING OPTION
This option will add conformal coating and other additional internal structural members to allow the unit to meet many portions of MIL-STD-810.

TURN ON SERVICE OPTION
We offer a turn on service that will ensure the Inverter has been properly installed and the full warranty is in effect (failures caused by incorrect installation are not covered by the warranty.) If this option is selected, the customer will also automatically receive an additional 3 months added to the warranty at no additional charge.

SPARE PARTS KIT OPTION
We offer a spare parts package that includes one of each board, spare fuses, spare semiconductors, and spare fans. These spare part kits are priced lower when ordered with the initial order then if they are ordered later on.

 

WARNING LEDs

When abnormal condition occurs, these LEDs will light to warn the user of the cause of the fault condition. Therefore all these LEDs are off under normal condition. These LEDs are:

RESERVE FAIL – Reserve AC input is abnormal either due to AC magnitude out of range or frequency out of range.

FUSE/TEMP - Either inverter fuse is open or over temperature has occurred.

OVERLOAD – Output is overloaded by over 110%, 125% or 150%

HIGH DC – This LED will light when DC input approaches high-line limit.

BAT LOW – This LED will light when the DC voltage is low.

BAT LOW STOP – This LED will light when the DC voltage is lower than specified range.

FAULT – The inverter is off due to abnormal conditions such as overload, short circuit, high DC, fuse over temperature, bypass breaker on emergency stop.

Since these LEDs are located behind the transparent window, the user can use them clearly without opening the door.

AUDIBLE ALARM

The audible alarm will beep under either one of the following conditions:

INVERTER IS OVERLOADED-
> 110% beep once every 3 seconds
> 125% beep once every second
> 150% beep twice every second

INVERTER IS SHORT CIRCUITED – Beeps continuously

FUSE OPEN
– Beeps continuously

HEAT SINK OVER TEMPERATURE
– Beeps continuously

HIGH DC SHUTDOWN
– Beeps continuously

BYPASS ON STOP
- Beeps continuously

EMERGENCY ON STOP
- Beeps continuously
The buzzer will also beep once every time the inverter is switched on or off to acknowledge to the user that his key entry is valid and accepted.

COMMUNICATIONS OPTIONS

We offer options for communications with this Inverter series. Some popular options available at additional cost include the following:

UPSCAN: This is a hand held remote display and control module with LCD and LED display that can monitor via RS-485 UP to 99 UPS Units at a remote distance of up to 3,000 feet.

UPSCALL: This is a modem that will automatically dial out to a specified number when an abnormal situation occurs.

NETAGENT: This provides capability to monitor the Inverter over the internet. It includes the appropriate additional SNMP card and microprocessor. The software required is provided by MEGATEC at additional cost.



Specifications for the Nova Jupiter 3 Phase Inverter Series

PHASE
DC Input/ 3-Phase Output
INVERTER  
Output Voltage (VAC)
Please Specify |120/208 |220/380 |230/400 |240/415 |277/480 |120 delta|220 3delta |240 3delta |380 3delta |480 3delta
Wave Form
Sinewave
Output Power Factor
0.7 lead to 0.7 lag
Frequency Lock Range
50 / 60 Hz + 0.1 Hz (crystal controlled)
Output Frequency (free running)
60Hz or 50Hz (please specify)
Phase Shift Under 100% Unbalanced Load
<0.5%
THD (Linear Load)
2% typical 3% max
Overload
<110%
Continuous
110-125%
Up to 15 minutes
125-150%
Up to 10 minutes
>150%
Up to 1 minute
Efficiency (100% Load)
89%
STATIC SWITCH (optional)  
Voltage Range
Same as AC output. (Different voltages are available upon request)
Mains <-> Inverter
0 ms (True Online)
Audible Noise
< 65dBA (at 1m)
Temperature
0-50ºC (32-122ºF) (Other ranges available)
Humidity
0%-95% (Non-condensing)
Altitude
Up to 1500 m Above Sea Level
EN50091-1, -2
Yes
Short Circuit Protection
Yes
Lightning / EMC Filter
MOV / Input & Output ( FCC CLASS A)
Galvanic Isolation
Output True Galvanic Isolation
LED, LCD, Audible Alarm
Yes
Remote Control / Communication Interface
Monitoring 1~99 Units simultaneously / Dry Contact, RS-232, RS-485 (Optional)