int_nav.gif

 
 
 
 
 
 

Other Products


Charts/Graphs

60 HZ MODELS
50 HZ MODELS
400 HZ MODELS
3 PHASE MODELS
SPECS/STD FEATURES
AVAILABLE OPTIONS

 

  RUGGED, LIGHTWEIGHT INVERTERS
 

 

120 VDC Nominal Input /
Pure Sine-Wave Output
GALAXY SERIES


The transformer isolated Galaxy Series Inverters are extremely rugged by design, and feature an optional advanced Internal Suppression Filter Network (ISFN) to suppress the significant transients usually associated with electric utility and military applications. The units are also extremely reliable, designed to provide many years of service in harsh shock, vibration, humidity, and EMI environments.

• Military programs, vehicular, shipboard
• AC Power from vehicle battery
• Communications
• Shelters
• Utility Applications


Click to Enlarge
Click here for specs (PDF)
 



105-150 VDC Operating Input / 120 VA - 10+ KVA
(Consult factory for higher power ratings)

 

60 HZ MODELS

UNIT
PICTURE
OUTLINE DWG. PDF
60 HZ
MODELS
OUTPUT
VAC
OUTPUT
FREQ(HZ)
CONTINUOUS
OUPUT
POWER
APPROX.
WEIGHT(LB)
SIZE
(HxWxL) INCHES
RACK PANEL
HEIGHT (IN)
OPT/STD
1260-120
120
60
120VA
20
5.25x6.5x9.75
5.25 OPT
2560-120
120
60
250VA
38
6.25x9.0x13.25
7.00 OPT
GS1K60-120
120
60
1KVA
87
5.25x19.00x22.00
5.25 STD
GS1.5K60-120
120
60
1.5KVA
105
5.25x19.00x22.00
5.25 STD
GS2K60-120
120
60
2KVA
120
5.25x19.00x22.00
5.25 STD
GS2.5K60-120
120
60
2.5KVA
125
8.75x19.00x21.25
8.75 STD
GS3K60-120
120
60
3KVA
130
8.75x19.00x21.25
8.75 STD
GS5K60-120
120
60
5KVA
140
8.75x19.00x21.25
8.75 STD

BACK TO TOP


50 HZ MODELS

UNIT
PICTURE
OUTLINE DWG. PDF
50 HZ
MODELS
OUTPUT
VAC
OUTPUT
FREQ(HZ)
CONTINUOUS
OUPUT
POWER
APPROX.
WEIGHT(LB)
SIZE
(HxWxL) INCHES
RACK PANEL
HEIGHT (IN)
OPT/STD
1250-120(220)
220
50
120VA
20
5.25x6.5x9.75
5.25 OPT
2550-120(220)
220
50
250VA
38
6.25x9.0x13.25
7.00 OPT
GS1K50-120 (220)
220
50
1KVA
87
5.25x19.00x22.00
5.25 STD
GS1.5K60-(220)
220
50
1.5KVA
105
5.25x19.00x22.00
5.25 STD
GS2K50-120 (220)
220
50
2KVA
120
5.25x19.00x22.00
5.25 STD
GS2.5K50-120 (220)
220
50
2.5KVA
125
8.75x19.00x21.25
8.75 STD
GS3K50-120 (220)
220
50
3KVA
130
8.75x19.00x21.25
8.75 STD
GS5K50-120 (220)
220
50
5KVA
140
8.75x19.00x21.25
8.75 STD

BACK TO TOP



400 HZ MODELS

UNIT
PICTURE
OUTLINE DWG. PDF
400HZ
MODELS
OUTPUT
VAC
OUTPUT
FREQ(HZ)
CONTINUOUS
OUPUT
POWER
APPROX.
WEIGHT(LB)
SIZE
(HxWxL) INCHES
RACK PANEL
HEIGHT (IN)
OPT/STD
1260-400(120)
120
400
120VA
20
5.25x6.5x9.75
5.25 OPT
2560-400(120)
120
400
250VA
38
6.25x9.0x13.25
7.00 OPT
GS1.5K400-(120)
120
400
1.5KVA
105
5.25x19.00x22.00
5.25 STD
GS2K400-120
115
400
2KVA
120
5.25x19.00x22.00
5.25 STD
GS2.5K400-120
115
400
2.5KVA
125
8.75x19.00x21.25
8.75 STD
GS3K400-120
115
400
3KVA
130
8.75x19.00x21.25
8.75 STD
GS5K400-120
115
400
5KVA
140
8.75x19.00x21.25
8.75 STD

BACK TO TOP



• Pure Sinewave Output
• Small Size
• Lightweight, extremely compact
• High reliability, MTBF exceeds 100,000 hours
• OV, O.L. and O.T. protected
• MTTR below 30 minutes; modular design
• Withstands high reactive load
• Tight voltage and frequency regulation
• Boards are conformal coated


Ruggedized to meet MIL-STD-810 shock,
vibration and humidity ("R" option)
Wide temperature range -40°C to +71°C
Special output voltages and frequencies
Provision for 3 Phase connection with 2 more identical units
19" Panel mount ("P1" option)
MS Connectors or outlets
Custom painting and marking
Handles
High inrush for motor start
Transfer switch to alternate AC source
Wall mount plate ("W" option)
Chassis slides (rack mount models only)
Switchable 50/60 Hz output
• RS232 or SNMP Communication
• Output fault alarm (relay closure)

 



Electrical
Input Voltage:
105 - 150 VDC (Extended range available)
Output Voltage:
See Table
Frequency:
50 Hz, 60 Hz, 400 Hz (+/-0.5%)
Frequency Regulation:
+/-0.5% N.L. to F.L.
Voltage Regulation:
+/-1.5% N.L. to F.L.
Efficiency:
Approximately 80% (depending on model)
Reactive Load:
0.75 Lead to 0.75 Lag
Distortion:
5% THD, 3% Single Harmonic
Overload:
125% for 5 minutes

Overload Protection Range: Automatic overload & short circuit protection
Sync & Phase Lock Range: +/-3 Hz, Typical (50/60 Hz models)
Transient Response: Approx. 1/4 cycle recovery to 95% of nominal



Operating Temp: -20°C to +50°C Standard -40°C to +71°C Optional
Cooling: By internal DC brushless fan
Vibration: Normal shipping and handling
Shock: 20g, 11 mS half sinewave
Humidity: To 95% RH non-condensing
EMI: Designed to meet FCC Part 15, Class A, Can meet MIL-STD-461 with additional filtering